Section 3 - Mower Preparation
20.
Ensure the shutoff valves (3) at the
bottom of the tank are in the open
position.
21.
Check the oil filter operating pressure.
-
When the oil is warm, with the pump
running, check the filter pressure
gauge (1).
Note: When the oil is cold, the gauge
may show that the filter needs
replacing. Allow the oil to warm
and check the filter gauge again.
-
If the gauge is in the green zone, the
filter is okay.
-
If the gauge is in the yellow zone, the
filter will need to be replaced soon.
-
If the gauge is in the red zone, replace
the filter immediately.
Note: See Section 5 “Maintenance” for
information on “Replacing the
Filter”.
Open Tank Shutoff Valves
214044C
Check Oil Filter Operating Pressure
216054C