11
•
Placing two fingers at the top of filter cartridge, press
down until the filter top clears the nylon top fitting.
•
Pull filter back and lift out of filter compartment.
•
Note that there is a removable filter base
that will be reused with the new filter.
Gently remove this from the old filter
cartridge and set aside. Discard old filter.
•
Unwrap new filter cartridge and locate
filter base.
•
Place a small film of Vaseline (optional to preserve o-
rings) on the filter base o-rings and gently press on-to
filter bottom.
•
Place filter/base assembly, base-first into filter
compartment. The filter base o-ring should fit into the
spring loaded pedestal receptacle.
•
Press down on the filter cartridge
while guiding the filter top so that it
clears filter compartment opening.
•
Push filter back far enough to allow
top-nylon fitting to seat into filter top
hole.
•
Verify that new filter is fully seated by rotating
horizontally ¼ turn. Rotation should be centered
without any wobble.
•
Turn water on and with filter door still removed, verify
that there are no leaks. With water running, press and
HOLD filter-life indicator reset button, until indicator
resets to “9999.”
Retain filter base
Insert new filter