Page 1: ...5 Stage Reverse Osmosis Drinking Water System with Booster Pump Installation Service Manual Assembled in USA...

Page 2: ...phisticated machine We strongly recommend using only licensed experienced technicians for installation and troubleshooting To locate the closest authorised service technician contact your dealer or vi...

Page 3: ...EM shown with standard faucet CONNECT YOUR SYSTEM TO THE COLD WATER SUPPLY ONLY DO NOT USE A WATER SUPPLY THAT IS MICRO BIOLOGICALLY UNSAFE OR OF UNKNOWN SOURCE WITHOUT ADEQUATE DISINFECTION BEFORE OR...

Page 4: ...ILLENNIUM RO SYSTEM shown with optional air gap faucet CONNECT YOUR SYSTEM TO THE COLD WATER SUPPLY ONLY DO NOT USE A WATER SUPPLY THAT IS MICRO BIOLOGICALLY UNSAFE OR OF UNKNOWN SOURCE WITHOUT ADEQUA...

Page 5: ...EFLON 5 Teflon Tape Used on all threaded fittings to prevent water leakage Eight rotations layers are adequate when using Teflon tape to secure any threaded fittings The Millennium RO already has Tefl...

Page 6: ...he 3 8 flex line from the base of cold water basin supply angle stop valve 4 Re connect the 3 8 JGV ASVPP1LF Angle Stop Valve to the basin supply angle stop valve 5 Re connect flex line to the JGV ASV...

Page 7: ...t stud will be accessible from below once the whole is completed 8 For Porcelain Sink Before starting the drill motor apply firm downward pressure on the bit until a crunching occurs This will help ke...

Page 8: ...cet connector MOUNTING THE FAUCET Standard Faucet 1 Drill a hole in the sink or the counter top or use an existing hole 2 Slide chrome cover plate and rubber gasket on to stem of faucet and place fauc...

Page 9: ...ng on screws 2 The storage tank may be laid on its side The bladder tank will function in both a horizontal or vertical position 3 The head assembly and or storage tank may be placed up to 10 feet fro...

Page 10: ...le the o ring provides a permanent leak proof seal 3 Push up to tube stop Fitting grips before it seals Ensure tube is pushed into the tube stop 2 Insert tube Cut the tube square It is essential that...

Page 11: ...available 8 During this initial fill period you will hear water being discharged through the red drain line This is normal as the contaminated water is being rejected by the reverse osmosis membrane T...

Page 12: ...supply to the system 2 Close storage tank ball valve 3 Open the dispensing faucet to depressurize the system Allow 2 to 3 minutes 4 Remove the filter housings by turning counter clockwise 5 Remove old...

Page 13: ...thoughTFCmembranesaredesignedfornonchlorinatedfeedsupply yourMillennium ROsystemis equippedwithdoublecarbonpre filtrationforchlorinereductionpriortotheTFCmembrane Stage 5 Carbon filter This Post filte...

Page 14: ...BLADDER IN TANK IS RUPTURED TANK MUST BE RE PLACED WITH NEW ONE 5 CHECK VALVE ON PRODUCT SIDE NOT HOLDING 1 REPLACE CHECK VALVE ON UNIT SLOW PRODUCTION 1 LOW WATER PRESSURE 1 MAKE SURE PUMP IS WORKIN...

Page 15: ...h the use inability to use or performance of the Millennium system Millennium is not responsible or liable for damage to any part of the Millennium system because of misuse misapplication negligence a...

Page 16: ...Assembled in USA...