CHAPTER 5
General Maintenance
Studio Command Series User Manual
61
5. Locate and
A
loosen the three lamp optimization
screws [A].
6. Look at the wall where the beam is projected
and use the three optimization screws to adjust
the lamp’s position within the fixture. until the
beam is at its maximum brightness and the
light level is even across the beam (or the “hot
spot” of brightness is at the center of the
beam).
Motor Gear Maintenance
Lubricating the motor gears with each lamp replacement will significantly extend gear life.
Referring to the figure below:
1. Unlatch and remove bezel.
2. Remove 2 screws [A] and lift the Dim/Shutter motor light shield [B].
3. Tilt the module to access the gear for each motor [C] and, supporting the gear, carefully
apply Krytox lubricant.
Caution: Using too much force in applying lubricant can bend
and damage gear.
4. Replace shield and bezel.
A
B
C