![Higen FDA6000C Series Скачать руководство пользователя страница 62](http://html1.mh-extra.com/html/higen/fda6000c-series/fda6000c-series_user-manual_2130183062.webp)
5. Parameter
Setting
5-13
Menu
Menu title
Description
Unit
Display range
Default
P2-18 Resonant FRQ[Hz]
Resonant Frequency
Hz
0 ~ 1000
300
P2-19
Resonant BW[Hz]
Frequency Band Width
Hz
0 ~ 1000
100
Input the band width of resonant frequency and resonant frequency band in [Hz].
1
0.707
Torque output
Torque output
frequency
Resonant
frequency
Resonant freq.
band width
[[SC LOOP Gain(P2-02)]]
Use resonant frequency greater than
6
[Hz]
Menu
Menu title
Description
Unit
Display range
Default
P2-20 De-Resonant ENB Resonant Removal Enable
0,1
0
0: Resonance removal operation stop
1: Resonance removal operating
Menu
Menu title
Description
Unit
Display range
Default
P2-21
Inertia Ratio
Inertia Ratio
Multiple
1.0 ~ 500.0
1.0
The system inertia is the sum of motor inertia and load inertia. This item sets the ratio of system
inertia to motor inertia in terms of [times].
System inertia (Motor load inertia)
Inertia Ratio =
Motor inertia
Menu
Menu title
Description
Unit
Display range
Default
P2-22
Autotune Range
Setting Range
0 ~ 9
0
Prior to using the automatic setting function, input approximate ratio of system inertia to motor
System inertia (Motor i load inertia)
Inertia =
Motor inertia
(to define the range)
If the ratio of system inertia to motor inertia is unknown, input "0".