Chapter 3. Wiring and Signals
3-3
[FDA6075C
□
Main circuit terminal]
1.Uses and wiring methods of FDA6001C
~6004C
are as follows.
1) The R, S and T terminals are used to connect main power supply of 3-phase AC 200~230 [V]
to the power circuits.
*
(Note)
Single-phase AC 220V may also be used; however, output may be lower than the rated
value. Install over current breaker on the main power supply input unit. Also, install
noise filter on the power supply input terminal to shut off noise coming from the power
lines.
2) Connect regenerative resistor between P and B terminals. The standard regenerative resistor
(See Table 3.1) is a standard item. (Install it on the electric panel.)
3) Connect the U, V and W phases of the servo motor to the U, V and W terminals.
4) Ground the terminal. Also connect the servo motor earth cable to this terminal.
[Table 3.1. Recommended parts to be installed on electric panel]
AC Servo drive system
FDA6001C
□
FDA6002C
□
FDA6004C
□
Wire thickness
AWG #16 ( 1.25 mm
2
)
Terminal in drive system
KET GP110012 (Maker : http://www.ket.com)
Switch
GMC - 12 ( 13A ) or equivalent (Maker : http://www.lgis.biz)
Breaker
ABS 33b ( 5A ) or equivalent (Maker : http://www.lgis.biz)
Noise filter
NFS 305 or NFS 310 (Maker : http://www.samilemc.com)
Standard regenerative resistor
(for P and B terminals)
50W 50
Ω
( Size: Refer to external view 1)
[External view 1 ] 50W 50
Ω
Ø4.3
78
±
0.5
90
±
1
6
43
±
1
500
±
20