Chapter 8. How to Use Position Servo
8-3
[Output status of ALARM CODES]
Alarm
type
Emerg.
Stop
Over-
current
Over-
voltage
Over-
load
Power
error
Encoder
miswiring
Others Normal
A_CODE0
ON OFF ON OFF
ON OFF ON OFF
A_CODE1 ON ON OFF OFF ON
ON OFF OFF
A_CODE2
ON ON ON ON
OFF OFF OFF
OFF
Where ON: Applicable contact is connected to "GND24".
OFF: Applicable contact is connected to "+24V", or applicable contact not connected.
8.2.3 Analog input use and function table
Name
Pin No.
Function and Use
TRQIN
27
Inputs external torque limit command (-10V ~ +10V).
PPFIN, PFIN
PPRIN, PRIN
11, 10
9, 12
Inputs position command pulse.
8.2.4 Analog output use and function table
Name
Pin No.
Function and Use
MONIT1
3
Monitor output 1 (-4V ~ +4V)
MONIT2
2
Monitor output 2 (-4V ~ +4V)
PAO, /PAO
7, 32
A phase, /A phase encoder signal output
PBO, /PBO
6, 31
B phase, /B phase encoder signal output
PZO, /PZO
5,30
Z phase, /Z phase encoder signal output
8.2.5 I/O contact power supply
Name
Pin No.
Function and Use
GND
1, 8, 26
33, 34, 36
Power ground for analog I/O, such as torque limit command,
monitor output and encoder output.
+24VIN
49
DC 24V power supply for the external I/O contact
GND24
24, 25
DC 24V ground for the external I/O contact
(Note)
See section 3.4.6 for the capacity of +24V power supply.
8.3 CN2 Wiring
For information on CN2 wiring, see "Section 3.5 CN2 Wiring and Signal Description".