c) Seat the drive by pressing the lever into the drive carrier. The drive will make a connection with the
connector on the drive board.
Figure 27: Drive Installed
4. Verify the drive is functional by identifying the Amber drive carrier LED is no longer indicating a fault. Identify
that the drive appears in the OS.
3.2
PSU Replacement
Table 28: Replacement Procedure Info
Time Required
# of People Required
Required Tools
5 minutes
1
None
1. Locate the failed PSU by identifying the illuminated Red LED on the PSU.
2. Place the CMA into the service position.
a) Unlatch the CMA at the elbow connector by pressing the blue release button to unlatch the connector
from the rail.
b) Swing the CMA away from the enclosure.