background image

• Enabling or disabling TPM

• Clearing the TPM

8.

Enable TPM functionality in the OS, such as Microsoft Windows BitLocker or measured boot.

For more information, see the 

Microsoft website

.

Enabling the Trusted Platform Module as TPM 1.2

Procedure

1.

During the server startup sequence, press the 

F9

 key to access 

System Utilities

.

2.

From the System Utilities screen select 

System Configuration

 > 

BIOS/Platform Configuration (RBSU)

Server Security

 > 

Trusted Platform Module options

.

3.

Change the "TPM Mode Switch Operation" to 

TPM 1.2

.

4.

Verify "TPM Visibility" is 

Visible

.

5.

Press the 

F10

 key to save your selection.

6.

When prompted to save the change in System Utilities, do one of the following:

• If in graphical mode, click 

Yes

.

• If in text mode, press the 

Y

 key.

7.

Press the 

ESC

 key to exit System Utilities.

The server reboots a second time without user input. During this reboot, the TPM setting becomes
effective.

8.

Enable TPM functionality in the OS, such as Microsoft Windows BitLocker or measured boot.

For more information, see the 

Microsoft website

.

Retaining the recovery key/password

The recovery key/password is generated during BitLocker setup, and can be saved and printed after
BitLocker is enabled. When using BitLocker, always retain the recovery key/password. The recovery key/
password is required to enter Recovery Mode after BitLocker detects a possible compromise of system
integrity.

To help ensure maximum security, observe the following guidelines when retaining the recovery key/
password:

• Always store the recovery key/password in multiple locations.

• Always store copies of the recovery key/password away from the server.

• Do not save the recovery key/password on the encrypted hard drive.

Hardware options installation

57

Содержание HPE ProLiant XL230k Gen10

Страница 1: ...tion 4 Abstract This document is for the person who installs administers and troubleshoots servers and storage systems Hewlett Packard Enterprise assumes that you are qualified in the servicing of com...

Страница 2: ...sion use or copying Consistent with FAR 12 211 and 12 212 Commercial Computer Software Computer Software Documentation and Technical Data for Commercial Items are licensed to the U S Government under...

Страница 3: ...ering up the chassis 15 Installing the operating system 15 Registering the server 15 Operations 16 Power down the server 16 Removing the hard drive blank 16 Removing a hot plug drive 17 Removing the s...

Страница 4: ...E Smart Storage Battery cabling 61 SUV cable connectors 62 Software and configuration utilities 63 Server mode 63 Product QuickSpecs 63 Active Health System Viewer 63 Active Health System 63 HPE iLO 5...

Страница 5: ...ecifications 78 Environmental specifications 78 Server specifications 78 Websites 79 Support and other resources 80 Accessing Hewlett Packard Enterprise Support 80 Accessing updates 80 Customer self r...

Страница 6: ...Front panel components Item Description 1 Serial number iLO information pull tab 2 SUV connector 3 Drive bay 1 4 Drive bay 2 5 Drive bay 3 6 Drive bay 4 7 Release latch Front panel LEDs and buttons 6...

Страница 7: ...irmware upgrade in progress 4 Hz cycle per sec iLO manual soft reboot sequence initiated 8 Hz cycle per sec iLO manual hard reboot sequence in progress Off Deactivated 1 When all four LEDs described i...

Страница 8: ...ate Solid blue The drive is being identified by a host application Flashing blue The drive carrier firmware is being updated or requires an update 2 Activity ring Rotating green Drive activity Off No...

Страница 9: ...configured and predicts the drive will fail Solid amber The drive has failed Off The drive is not configured by a RAID controller or a spare drive NVMe drive components and LEDs Item Description 1 Rel...

Страница 10: ...Chassis server bay numbering Chassis I O module bay numbering 10 Component identification...

Страница 11: ...e A connector Processor 1 9 SATA cable connector 10 Front panel USB cable connector 11 M 2 cable connector 12 Trusted Platform Module 13 Front panel SUV cable connector 14 Front panel LED cable connec...

Страница 12: ...nfiguration NVMe is not supported 3 In a single processor configuration Mezzanine B is not supported Processor heatsink and socket components Item Description 1 Heatsink nuts 2 Processor carrier 3 Pin...

Страница 13: ...ttings S7 Off Reserved S8 Reserved S9 Reserved S10 Reserved S11 Reserved S12 Reserved 1 To access the redundant ROM set S1 S5 and S6 to On 2 When the system maintenance switch position 6 is set to the...

Страница 14: ...o Apollok6000 docs Installing hardware options Install any hardware options before initializing the server For options installation information see the option documentation For server specific informa...

Страница 15: ...install an operating system on the server use one of the following methods Insert the operating system CD into the USB attached DVD ROM drive user provided and reboot the server Download the Service P...

Страница 16: ...d the OS If an application stops responding you can use this method to force a shutdown Use a virtual power button selection through iLO 5 This method initiates a controlled remote shutdown of applica...

Страница 17: ...LED definitions on page 8 2 Back up all server data on the drive 3 Remove the drive Removing the server CAUTION For proper cooling do not operate the server without the access panel baffles expansion...

Страница 18: ...n the opposite side Procedure 1 Power down the server Power down the server on page 16 2 Remove the server Removing the server on page 17 3 Place the server on a flat level work surface 4 Remove the a...

Страница 19: ...rt Storage Battery or the M 2 enablement backplane might be installed on the front bracket Removing a server blank CAUTION To prevent improper cooling and thermal damage do not operate the chassis unl...

Страница 20: ...less all bays are populated with a component or a blank IMPORTANT The left and right sides of the chassis are oriented 180 from each other Components installed on one side of the chassis must be turne...

Страница 21: ...when they are installed on the opposite side Procedure 1 Power down the server Power down the server on page 16 2 Remove the server Removing the server on page 17 3 Place the server on a flat level wo...

Страница 22: ...re that all cables are routed to the sides of the server If the baffle will not seat properly you may need to move the cables to their original position 3 Close the front bracket 4 Install the access...

Страница 23: ...2 Remove the server Removing the server on page 17 3 Place the server on a flat level work surface 4 Remove the access panel Removing the access panel on page 18 5 Remove the rear support bracket To...

Страница 24: ...e Drives The server supports up to four SFF drives Drive guidelines When adding drives to the server observe the following general guidelines The system automatically sets all device numbers If only o...

Страница 25: ...LED definitions on page 8 Installing an NVMe drive CAUTION To prevent improper cooling and thermal damage do not operate the server unless all drive and device bays are populated with either a compone...

Страница 26: ...opposite side IMPORTANT In a single processor configuration processor 2 is not used IMPORTANT HPE ProLiant and HPE Synergy Gen10 server products do not support upgrading to Second Generation Intel Xeo...

Страница 27: ...instructions see the Hewlett Packard Enterprise Support Center website CAUTION THE CONTACTS ARE VERY FRAGILE AND EASILY DAMAGED To avoid damage to the socket or processor do not touch the contacts 2 P...

Страница 28: ...on the processor frame and the socket c Align the processor heatsink assembly with the alignment pins and gently lower it down until it sits evenly on the socket The heatsink alignment pins are keyed...

Страница 29: ...led in the server must be of the same type DIMM population information For specific DIMM population information see the DIMM population guidelines on the Hewlett Packard Enterprise website http www hp...

Страница 30: ...attached to the DIMM The information in this section helps you to use the label to locate specific information about the DIMM Item Description Example 1 Capacity 8 GB 16 GB 32 GB 64 GB 128 GB 2 Rank 1...

Страница 31: ...the air baffle and drive blanks must be installed when the server is powered up CAUTION To avoid damage to the DIMM insert it into the slot by pressing down gently on each side IMPORTANT The left and...

Страница 32: ...en To configure the memory mode use UEFI System Utilities see UEFI System Utilities on page 67 Installing the cable retention clip You can install an optional cable retention clip that attaches to the...

Страница 33: ...7 Center the fastener on the front edge of the cable retention clip to the cable connector 8 Slide the cable retention clip forward to lock it into place Hardware options installation 33...

Страница 34: ...assis Installing the server on page 14 14 Press the Power On Standby button The server exits standby mode and applies full power to the system The system power LED changes from amber to flashing green...

Страница 35: ...nfiguration Procedure 1 Power down the server Power down the server on page 16 2 Remove the server Removing the server on page 17 3 Place the server on a flat level work surface 4 Remove the access pa...

Страница 36: ...9 Route and connect the cables Single mezzanine card configuration Dual mezzanine card configuration 36 Hardware options installation...

Страница 37: ...Single EDR mezzanine with fabric management cable Dual EDR mezzanines with fabric management cable Hardware options installation 37...

Страница 38: ...e The server supports the following PCIe I O riser options HPE XL230k x16 LP PCIe External I O Riser Kit HPE XL230k x8 PCIe Internal External I O Riser Kit HPE XL230k x8 PCIe Internal I O Riser Kit NO...

Страница 39: ...r support bracket on page 22 8 Install the PCIe riser assembly onto the rear bracket 9 Align the arrows on the PCIe riser assembly with the arrows on the server tray and then install the assembly 10 I...

Страница 40: ...d Enterprise website http www hpe com info qs CAUTION To prevent electrical damage always power down the server associated with the I O module before installing the I O module CAUTION Remove the serve...

Страница 41: ...ORTANT The left and right sides of the chassis are oriented 180 from each other Components that are installed on one side of the chassis must be turned 180 when they are installed on the opposite side...

Страница 42: ...Procedure 1 If installed remove the I O module from the chassis 2 Remove the riser cover 3 Install the expansion board 42 Hardware options installation...

Страница 43: ...4 Install the riser cover 5 Install the riser into the I O module Hardware options installation 43...

Страница 44: ...de Procedure 1 Power down the server Power down the server on page 16 2 Remove the server Removing the server on page 17 3 Place the server on a flat level work surface 4 Remove the access panel Remov...

Страница 45: ...2 backplane adapter and then secure it with T 10 flat head screws 9 Align the guide brackets so that each bracket faces the other and then secure the brackets with pan head screws Hardware options in...

Страница 46: ...10 Install up to two M 2 SSD drives onto the backplane 11 Install the M 2 backplane Be sure that the backplane is fully seated and that the guide brackets are closed 46 Hardware options installation...

Страница 47: ...12 Connect the cable to the adapter and then close the bracket 13 Remove the rear support bracket screws Hardware options installation 47...

Страница 48: ...ezzanine card while maintaining the cable connection between the mezzanine card and the rear support bracket b If the PCIe riser is installed remove the screw securing the rear support bracket to the...

Страница 49: ...15 Route and connect the cable to the system board 16 Install the mezzanine card Hardware options installation 49...

Страница 50: ...le Installing the air baffle on page 22 19 Close the front bracket 20 Install the access panel 21 Install the server into the chassis Installing the server on page 14 22 Press the Power On Standby but...

Страница 51: ...Remove the server Removing the server on page 17 3 Place the server on a flat level work surface 4 Remove the access panel Removing the access panel on page 18 5 Open the front bracket Opening the fr...

Страница 52: ...the Trusted Platform Module 3 Retaining the recovery key password HPE TPM 2 0 installation is supported with specific operating system support such as Microsoft Windows Server 2012 R2 and later For mo...

Страница 53: ...rom the system board can damage the TPM cover the TPM and the system board If the TPM is removed from the original server and powered up on a different server data stored in the TPM including keys wil...

Страница 54: ...ecessary Remove the server or server blade from the chassis 6 Place the server on a flat level work surface 7 Remove the access panel 8 Remove any options or cables that may prevent access to the TPM...

Страница 55: ...to place firmly press straight down on the middle of the cover 4 Proceed to Preparing the server for operation on page 55 Preparing the server for operation Procedure 1 Install any options or cables p...

Страница 56: ...ence press the F9 key to access System Utilities 2 From the System Utilities screen select System Configuration BIOS Platform Configuration RBSU Server Security Trusted Platform Module options 3 Verif...

Страница 57: ...key to exit System Utilities The server reboots a second time without user input During this reboot the TPM setting becomes effective 8 Enable TPM functionality in the OS such as Microsoft Windows Bi...

Страница 58: ...Cabling Front panel LED board assembly cabling SATA drive cabling 58 Cabling...

Страница 59: ...M 2 SSD cabling Mezzanine card cabling Single mezzanine configuration Dual mezzanine configuration NOTE Mezzanine B is not supported in a single processor configuration Cabling 59...

Страница 60: ...Single EDR mezzanine with fabric management cable Dual EDR mezzanines with fabric management cable NOTE Mezzanine B is not supported in a single processor configuration 60 Cabling...

Страница 61: ...NVMe backplane cabling NOTE NVMe is not supported in a single processor configuration HPE Smart Storage Battery cabling NOTE This server supports only the HPE Smart Storage Battery Cabling 61...

Страница 62: ...lt in damage to the equipment Item Connector Description 1 Serial For trained personnel to connect a null modem serial cable and perform advanced diagnostic procedures 2 USB1 For connecting up to two...

Страница 63: ...QuickSpecs For more information about product features specifications options configurations and compatibility see the product QuickSpecs on the Hewlett Packard Enterprise website http www hpe com in...

Страница 64: ...o download the Active Health System Log and send it to a support professional to help you resolve an issue When you download and send Active Health System data to Hewlett Packard Enterprise you agree...

Страница 65: ...deration pages but a license is required for using the following features Group Virtual Media Group power control Group power capping Group configuration and Group firmware update For more information...

Страница 66: ...iLO advanced functionality The iLO Amplifier Pack performs rapid server discovery and inventory for thousands of supported servers for the purpose of updating firmware and drivers at scale For more in...

Страница 67: ...or high volume server deployments The STK is designed to support ProLiant servers The toolkit includes a modular set of utilities and important documentation that describes how to apply these tools to...

Страница 68: ...enabled Procedure 1 From the System Utilities screen select System Configuration BIOS Platform Configuration RBSU Boot Options Boot Mode 2 Select a setting UEFI Mode default Configures the system to b...

Страница 69: ...environment for scripting and running UEFI applications including UEFI boot loaders The Shell also provides CLI based commands you can use to obtain system information and to configure and update the...

Страница 70: ...Packard Enterprise website USB support Hewlett Packard Enterprise Gen10 servers support all USB operating speeds depending on the device that is connected to the server External USB functionality Hew...

Страница 71: ...Moonshot infrastructures and associated options up to date and secure SUM identifies associated nodes you can update at the same time to avoid interdependency issues Key features of SUM include Disco...

Страница 72: ...the dashboard SPP A comprehensive systems software and firmware update solution which is delivered as a single ISO image SUM A tool for firmware and driver maintenance for HPE ProLiant servers and ass...

Страница 73: ...component provides updated system firmware that can be installed directly on supported operating systems Additionally when used in conjunction with SUM this Smart Component allows the user to update...

Страница 74: ...tributes Operational Support Services enable you to choose the right service level length of coverage and response time to fit your business needs For more information see the Hewlett Packard Enterpri...

Страница 75: ...tenance Error Message Guide for HPE ProLiant Gen10 servers and HPE Synergy provides a list of error messages and information to assist with interpreting and resolving error messages Integrated Managem...

Страница 76: ...tery to temperatures higher than 60 C 140 F Do not disassemble crush puncture short external contacts or dispose of in fire or water Replace only with the spare designated for this product Procedure 1...

Страница 77: ...ng the battery reconfigure the system through UEFI System Utilities UEFI System Utilities on page 67 To replace the component reverse the removal procedure For more information about battery replaceme...

Страница 78: ...is applicable No direct sunlight is allowed 2 Storage maximum humidity of 95 is based on a maximum temperature of 45 C 113 F Altitude maximum for storage corresponds to a pressure minimum of 70 kPa Fo...

Страница 79: ...brary www hpe com info EIL Single Point of Connectivity Knowledge SPOCK Storage compatibility matrix www hpe com storage spock Storage white papers and analyst reports www hpe com storage whitepapers...

Страница 80: ...tes through the product interface Review your product documentation to identify the recommended software update method To download product updates Hewlett Packard Enterprise Support Center www hpe com...

Страница 81: ...cate that information Remote support and Proactive Care information HPE Get Connected www hpe com services getconnected HPE Proactive Care services www hpe com services proactivecare HPE Proactive Car...

Страница 82: ...fo reach For Hewlett Packard Enterprise product environmental and safety information and compliance data including RoHS and REACH see www hpe com info ecodata For Hewlett Packard Enterprise environmen...

Отзывы: