The slot locations in which each memory module is installed. These components must be installed in the same
locations on the new system board.
◦
The port numbers and cable connections between the system board and the secondary riser board.
• Before you perform this procedure, make sure that you have a T-15 and T-30 Torx screwdrivers available.
Procedure
1.
2.
Disconnect all peripheral cables from the server.
3.
Remove the server from the chassis.
4.
5.
Do one of the following:
•
Remove the secondary riser blank.
•
Remove the secondary riser cage.
6.
Do one the following:
•
Remove the primary riser blank.
•
Remove the primary riser cage.
7.
If installed,
remove the Media Module adapter.
8.
If installed,
remove the M.2 SSD riser board.
9.
disconnect the S100i SR Gen10 controller SATA X-cable.
10. Remove the DIMMs from the system board.
11. Remove the processor heatsink assembly:
a. Allow the heatsink to cool.
b. Loosen the heatsink nuts in the order specified by the label on the heatsink.
Removal and replacement procedures
63