Description
Chassis
Fan configuration
Number of drives
supported by the server
Maximum inlet ambient
temperature
Apollo r2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 4 drives
Not supported
HPE Persistent
Memory module
Apollo r2200
Gen10 Chassis
(12 LFF
backplane)
Redundant and
nonredundant
3 drives
Not supported
3 drives
Not supported
Not supported
Not supported
Apollo r2600
Gen10 Chassis
(24 SFF or 16
SFF + 8 NVMe
backplane)
Redundant and
nonredundant
0 to 6 drives
Not supported
Not supported
Apollo r2800
Gen10 Chassis
(24 SFF
backplane with
SAS expander)
Redundant and
nonredundant
0 to 24 drives
Not supported
Apollo r2800
Gen10 Chassis
(16 NVMe
backplane)
0 to 4 drives
Not supported
The drive capacity must be less than 10 TB.
The drive capacity must be greater than or equal to 10 TB.
If the component is installed in server 1 or server 2, and the server is installed in the Apollo r2200 Gen10 Chassis, drive blanks must be
installed in drive bays 1-2 and 2-2. Similarly, if the component is installed in server 3 or server 4, and the server is installed in the Apollo
r2200 Gen10 Chassis, drive blanks must be installed in drive bays 3-2 and 4-2.
If the component is installed in server 1 or server 2, and the server is installed in the Apollo r2200 Gen10 Chassis, bezel blanks must be
installed in drive bays 1-2 and 2-2. Similarly, if the component is installed in server 3 or server 4, and the server is installed in the Apollo
r2200 Gen10 Chassis, bezel blanks must be installed in drive bays 3-2 and 4-2.
If the component is installed in server 1 or server 2, and the server is installed in the Apollo r2600 Gen10 Chassis, bezel blanks must be
installed in drive bays 1-3, 1-4, 1-5, 1-6, 2-3, 2-4, 2-5 and 2-6. Similarly, if the component is installed in server 3 or server 4, and the
server is installed in the Apollo r2600 Gen10 Chassis, bezel blanks must be installed in drive bays 3-3, 3-4, 3-5, 3-6, 4-3, 4-4, 4-5 and
4-6.
HPE Smart Array controllers
CAUTION: To prevent improper cooling and thermal damage, do not keep an energy pack inside the chassis when
the Smart Array P-class controller is not installed.
Specifications