Procedure
1.
Access System Utilities. During POST, press
F9.
2.
On the System Utilities home screen, select
System Configuration > BIOS/Platform Configuration (RBSU) >
Advanced Options > Advanced Service Options.
3.
Select the Serial Number field and press
Enter.
The following alert appears:
The serial number is modified by qualified service personnel and must
match the serial number located on the chassis.
4.
Click
OK.
5.
Type the serial number and press
Enter.
6.
Select the Product ID field and press
Enter.
The following alert appears:
Product ID is modified only by qualified personnel. This value must match
the product ID located on the chassis.
7.
Type the product ID and press
Enter.
8.
Press
F10 to save the configuration.
9.
If the server is using Intel Xeon Gold 6244 processors, do the following:
a. Select System Configuration > BIOS/Platform Configuration (RBSU) > Advanced Options > Fan and
Thermal Options > Thermal Configuration.
b. Select one of the following advanced fan cooling method:
•
Enhanced CPU Cooling
•
Maximum Cooling
10. Save your setting.
The procedure is complete.
System battery replacement
System battery information
The server contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery that provides
power to the real-time clock. If this battery is not properly handled, a risk of the fire and burns exists. To reduce the risk of
personal injury:
• Do not attempt to recharge the battery.
• Do not expose the battery to temperatures higher than 60°C (140°F).
• Do not expose the battery to extremely low air pressure as it might lead to explosion or leakage of flammable liquid or
gas.
Removal and replacement procedures
67
Содержание HPE ProLiant XL170r Gen10
Страница 6: ...Acronyms and abbreviations 128 6...
Страница 22: ...22 Customer self repair...
Страница 23: ...Customer self repair 23...
Страница 24: ...24 Customer self repair...
Страница 95: ...InfiniBand and auxiliary adapter cabling Cable color Description Orange White cable Blue Black cable Cabling 95...