background image

22 | 23

CLICK !

72 mm

32 mm

9 mm

18 mm

 A

 B

20,5

22,5

 B

82796.****

83149.****

83093.****

A

20,5

max. 200 mm

1

4

3

2

3

2

1

3

7

32

Drawers with Hettich guiding rail Actro YOU/ Actro 5D.

Assembly of the basic profile.

In order to integrate the basic profile for drawer guidings rails into  
the CADRO frame system, it is advisable to place a connector at the  
lower profile connection position 

 B

. Thus, a stabilizing cross profile  

can also be integrated at this position. 

1

Fixing at the upper position 

 A

 is done using the connecting arm  

83093.**** which is screwed into a 4 mm core bore. The basic profile  
is provided with holes for the ususal M5 grub screws being drilled at the  
specified distances …

2

… and then being fixed by screwing.

3

Another possibility to connect the profiles without connecting nodes is 

the use of the universal connectors 

(see page 24)

.

Attaching the guiding rail.

The basic profile

, order no. 9 298 806 / 9 298 807,

 is perfectly adapted 

to  the  Hettich  drawers.  It  is  provided  with  a  groove,  on  which  the 
predrillings  for  mounting  the 

runners

  “Actro  YOU/Actro  5D” 

precisely can be placed.

1

  For drawers with offset fronts the first drilling position is to be 

placed at a 37 mm distance (measured from the front edge of the  
carcass). In case of inset fronts, the position is shifted backwards  
according to the thickness of the front. The number and position of  
the drillings depends on the depth of the respective drawer and its  
planned load capacity. In order to connect the Actro

 runner 

to  the 

CADRO drawer profile, we recommend the use of a M5 x 11 mm 
countersunk head screw

 Ø 3,6 x 8 mm, order no. 9 217 435

.

 Predrilling 

of the profile with Ø 3,5 mm

.

2

  The guiding rails are exactly mounted and to attach the cover profile

 

order no. 9 298 808 / 9 298 809 

(one-sided covering) or

 order no. 9 298 810 / 

9 298 811

 (two-sided covering) the top of the basic profile is provided with 

the clip

, order no. 9 304 915

. We recommend the use of one clip after every 

20 cm.

3

  Now the required cover profile can be firmly clipped on to hide the 

guiding mechanism.

4

  To cover one side of the basic profile, the cover profile

 order no. 

9 298 808 / 9 298 809

 is used. Two-sided covering ist provided by the profile 

order no. 9 298 810 / 9 298 811.

72 mm

32 mm

9 mm

18 mm

 A

 B

 B

Basic profile for Hettich drawer

83149.**** 

Cover profile

9 298 808 / 9 298 809

to cover  
one side

Cover profile

9 298 810 / 9 298 811

to cover 
two sides

CADRO Base.

82796.****

Threaded pin

M5 x 6 mm
82918.****

Universal connector

82937.****

83149.****

83093.****

 

A

 B

A

countersunk screw

Ø 3,6 x 8 mm
9 217 435

Содержание CADRO

Страница 1: ...Rahmensystem Technical Information and Assembly...

Страница 2: ...apping jig 10 11 Structure and function Positions of the stop plate Optional sets Assembly 12 13 Tools Order of assembly Cleaning Attachment 14 15 The invisible wall mounting The alternative wall moun...

Страница 3: ...cture and function Positions of the stop plate Optional sets Assembly 12 13 Tools Order of assembly Cleaning Attachment 14 15 The invisible wall mounting The alternative wall mounting Load capacity of...

Страница 4: ...s elements Dimensions of the elements using an example Preparation of the profiles 32 Inserting of the screws Silicon piping profile Sealing tape Assembly 33 35 Glass door hinges 36 37 Mounting of the...

Страница 5: ...les Power supply 29 Cable outlet Plug mounting CONEXIS CADRO Glass display case 30 37 Frames for glass panels 30 31 The principle Drilling Glass elements Dimensions of the elements using an example Pr...

Страница 6: ...ent profiles and connectors please refer to our cataloque CADRO frame system Basic assembly of each CADRO piece of furniture CADRO Base The safe connection The pins are optionally supplied with a thre...

Страница 7: ...O piece of furniture CADRO Base The safe connection The pins are optionally supplied with a thread securing glue and fastened with a 0 8 1 Nm torque The M5 grub screws are fixed in the surrounding con...

Страница 8: ...y they can also be covered with cover caps Grub screws of the size M5 x 6 mm DIN 913 are used to link the con nectors with the profiles These are simply being screwed into the 4 5 mm drill hole with a...

Страница 9: ...illing or milling chips must now again be removed with compressed air Inserting of the grub screws For the most popular 2 profile colours we offer the matching threaded pins which discreetly fit into...

Страница 10: ...t positions for the stop plate Center hole for the positioning on the pillar drilling machine position of the drill Fixing points for optional sets e g sliding door profiles Optional sets e g for slid...

Страница 11: ...t positions for the stop plate Center hole for the positioning on the pillar drilling machine position of the drill Fixing points for optional sets e g sliding door profiles Optional sets e g for slid...

Страница 12: ...ghtening the grub screw During the assembly take care that the screws are placed in a well hidden or non visible area It is important as described in steps 2 6 to assemble modules that afterwards are...

Страница 13: ...ghtening the grub screw During the assembly take care that the screws are placed in a well hidden or non visible area It is important as described in steps 2 6 to assemble modules that afterwards are...

Страница 14: ...mum distance of 48 mm between the upper edge of the milling and the end of the profile is observed 2 Afterwards drill a hole in the right or left side of the profile next to the milling with subsequen...

Страница 15: ...e s end 3 5 12 5 Wall Wall Wall Base Connection to a top or a bottom Profil Cover cap 82922 Connection to a top or a bottom Threaded pin M5 x 6 mm DIN 913 for securing the connection Fastening sleeve...

Страница 16: ...plungers Thanks to an integrated metal spring under the ball the side or rear panel simply can be clicked in Thus the fixing system remains invisible from the outside as well as from the inside 1 The...

Страница 17: ...pprox 2 mm Ball spring plungers Thanks to an integrated metal spring under the ball the side or rear panel simply can be clicked in Thus the fixing system remains invisible from the outside as well as...

Страница 18: ...side door view from the inside Door outside the frame system Outside door view from the inside Door outside the frame system Door inside the frame system Guiding groove of the profile Guiding groove o...

Страница 19: ...system Overlay door view from the inside Overlay door Inset door Guiding groove of the profile Guiding groove of the profile Handle strip CADRO Line Aluminium Railing handle Zamac and aluminium Speci...

Страница 20: ...Drilling dimensions Drilling dimensions Profile on top Profile on top Profile at the bottom Profile at the bottom Top profile 9 298 798 9 298 799 Bottom profile 9 298 800 9 298 801 SlideLine M with d...

Страница 21: ...ng dimensions Top profile 82914 Profile on top Profile on top Profile at the bottom Profile at the bottom Top profile 83105 Bottom profile 82913 Bottom profile 83104 SlideLine M with damping system Sl...

Страница 22: ...planned load capacity In order to connect the Actro guiding rail to the CADRO drawer profile we recommend the use of a M5 x 11 mm countersunk head screw 2 The guiding rails are exactly mounted and to...

Страница 23: ...d at a 37 mm distance measured from the front edge of the carcass In case of inset fronts the position is shifted backwards according to the thickness of the front The number and position of the drill...

Страница 24: ...Stand 82931 Connecting thread 82938 E g 3 way connector with stand 82948 1 Each of the two profile ends to be joined must be cut at a 45 angle 2 With a distance of 40 mm stop plate F2 to the upper end...

Страница 25: ...Connecting thread 9 298 853 E g 3 way connector with stand 9 298 831 9 298 832 Corner connector 1 Each of the two profile ends to be joined must be cut at a 45 angle 2 With a distance of 40 mm stop pl...

Страница 26: ...en illuminated from the sides 2 The planning includes therefore the position of the lighting profiles fitted with LED strips and the resulting guidance of the cables to the cable exit and finally to t...

Страница 27: ...ls with a thickness of 6 mm These are then illuminated from the sides 2 The planning includes therefore the position of the lighting profiles fitted with LED strips and the resulting guidance of the c...

Страница 28: ...d through the connector for power supply towards the outside that is usually towards the wall in case of hanging furniture mostly upwards as for standing furniture also downwards For the connection to...

Страница 29: ...le power supply the cables are guided through the lighting profiles to the connector for power supply being covered afterwards by a cover profile which matches the colour of the frame PLEASE NOTE Expe...

Страница 30: ...lso use the fixing stop plate F1 of our drilling jig to drill the holes in the glass panel profiles What is special here is that the drilling and screwing is done at the inside of the profiles and thu...

Страница 31: ...s You can also use the fixing stop plate F1 of our drilling jig to drill the holes in the glass panel profiles What is special here is that the drilling and screwing is done at the inside of the profi...

Страница 32: ...inserting the glass panels the required sides are equipped with pieces of the silicon piping profile order no 9 303 926 We recommend the use of one piece at each profile end and another one every 25...

Страница 33: ...re to be firmly mounted in the glass display case a 2 mm wide self adhesive sealing strip is attached on the inner profile edges 83170 Thus the glass panels can be precisely and securely be fixed Asse...

Страница 34: ...f its larger width it neatly covers the frame profile in the area where no glass panel is firmly installed 11 Now the door can be inserted with the help of the accessories see following pages RECOMMEN...

Страница 35: ...ed Because of its larger width it neatly covers the frame profile in the area where no glass panel is firmly installed 11 Now the door can be inserted with the help of the accessories see following pa...

Страница 36: ...drilling positions for the top and bottom hinge and the ball spring plungers are arranged oppositely at the same positions depending on the size of the glass door A As a rule the door is all around 4...

Страница 37: ...or the top and bottom hinge and the ball spring plungers are arranged oppositely at the same positions depending on the size of the glass door A As a rule the door is all around 4 mm smaller than the...

Страница 38: ...removed so that the lock can be stuck to the glass door 2 In order to fix the lock at the accurate position the lock cylinder must be at first passed through the hole in the glass door Then 1 place t...

Страница 39: ...removed so that the lock can be stuck to the glass door 2 In order to fix the lock at the accurate position the lock cylinder must be at first passed through the hole in the glass door Then 1 place t...

Страница 40: ...also be used as a glass shelf support inside the diplay case and be mounted inside the profiles at any desired height Slight differences in height can precisely be adjusted using the eccentric cover...

Страница 41: ...m Hinge Hinge 18 5 mm 18 5 mm Glass shelf Glass shelf Glass shelf Glass shelf Glass shelf Glass shelf Glass shelf Glass shelf Generally glass shelves are mounted in a way that they are inserted in the...

Страница 42: ...inge Hinge 18 5 mm 18 5 mm Glass shelf Glass shelf Glass shelf Glass shelf Glass shelf Glass shelf Glass shelf Glass shelf Generally glass shelves are mounted in a way that they are inserted in the fr...

Страница 43: ...n the lighting clip on profiles At the same time they help to fix the glass panes securely within the frame Laying of the cables 3 The cables are now guided towards the connector with cable exit see a...

Страница 44: ...c clip on profiles where no illumination is needed and no cables need to be installed according to the planning see also page 34 35 Attachment of the LED lighting strips 1 Now the self adhesive LED st...

Страница 45: ...or The set including the clamp 83172 offers the possibility to mount the frame at two different distances by choosing the required angle A B For example in order to bridge baseboards without any probl...

Страница 46: ...llel to a wall ceiling or floor The set including the clamp offers the possibility to mount the frame at two different distances by choosing the required angle A B For example in order to bridge baseb...

Страница 47: ...06_2022_HMV...

Отзывы: