2.5. Frequencies and addressing
Radio remote control systems from HETRONIC include a CS434, CS447 or
CS458 RF module synthesizer (not subject to registration), which incorporates
an RF transmitter module and an RF receiver module.
2.5.1. Frequency allocation for CS434
FREQUENCY ALLOCATION FOR CS434TXN
MANUAL
SETTING
AUTOMATIC SETTING
S1 = 0
S1 = 1
D2 = 1 = FCS (Free Channel Search TX), and SCAN-RX
D2
D3
D4
D5
D6
Frequency
Channels
D3 = 1 = AUTX (Automatic Channel Change TX), and SCAN-RX
0 0 0 0 0 433.1000
2
0
0
0
0
1
433.5500
20
Freq Group for FCS/AUTX/SCAN
0 0 0 1 0 434.0500
40
D4
D5
D6
Channels
0 0 0 1 1 434.0750
41 0
0
0
68, 58, 54, 52, 49, 41
0 0 1 0 0 434.1000
42 0
0
1
67, 59, 55, 53, 47, 44
0 0 1 0 1 434.1250
43 0
1
0
66, 64, 61, 57, 51, 43
0 0 1 1 0 434.1500
44 0
1
1
65, 63, 60, 56, 50, 42
0 0 1 1 1 434.1750
45
1
0
0
38, 32, 28, 18, 10, 8, 5
0 1 0 0 0 434.2000
46
1
0
1
37, 29, 25, 23, 17, 14, 4
0 1 0 0 1 434.2250
47
1
1
0
36, 34, 31, 27, 21, 13, 3
0 1 0 1 0 434.2500
48
1
1
1
35, 33, 30, 26, 20, 12, 2
0 1 0 1 1 434.2750
49
0 1 1 0 0 434.3000
50
If FCS is selected,
0 1 1 0 1 434.3250
51
the module will remember the last frequency that is set and then the
0 1 1 1 0 434.3500
52
frequency change is made by pushing the decrement switch button.
0 1 1 1 1 434.3750
53
FCS on the transmitter module will only work with decrement switch
button.
1 0 0 0 0 434.4000
54
1 0 0 0 1 434.4250
55
In AUTX mode, the TX module will remember the last frequency
1 0 0 1 0 434.4500
56
and then it will automatically decrement the channel everytime
1 0 0 1 1 434.4750
57
it is cycled On-Off-On.
1 0 1 0 0 434.5000
58
1 0 1 0 1 434.5250
59
In both, AUTX and FCS mode, the decrement switch button is
1 0 1 1 0 434.5500
60
always
active.
1 0 1 1 1 434.5750
61
Thus, the user can change the frequency by pushing the button.
1 1 0 0 0 434.6000
62
1 1 0 0 1 434.6250
63
1 1 0 1 0 434.6500
64
1 1 0 1 1 434.6750
65
1 1 1 0 0 434.7000
66
1 1 1 0 1 434.7250
67
1 1 1 1 0 434.7500
68
1 1 1 1 1 434.7750
69
Maximum power is 10mW ERP, 100% duty cycle in
Europe
Maximum power is 1mW ERP, 100% duty cycle in
Europe