73
-
Pandar128 Channel Distribution (Continued)
Channel
#
Angular Position
Instrument Range
Near Field
Enabled?
Max. Range
@10% Reflectivity
Far Field
Enhanced?
Min. Reflectivity @ Max.
Instrument Range
High-
Res?
Horiz. Offset
Vertical
Min
Max
121
-1.145°
-21.379°
2.85 m
100 m
-
25 m
-
100 m @ 1600%
-
122
-3.436°
-21.848°
2.85 m
100 m
-
25 m
-
100 m @ 1600%
-
123
-1.146°
-22.304°
0.3 m
100 m
YES
25 m
-
100 m @ 1600%
-
124
-3.440°
-22.768°
2.85 m
100 m
-
25 m
-
100 m @ 1600%
-
125
-1.146°
-23.219°
2.85 m
100 m
-
25 m
-
100 m @ 1600%
-
126
-3.443°
-23.678°
0.3 m
100 m
YES
25 m
-
100 m @ 1600%
-
127
-3.446°
-24.123°
2.85 m
100 m
-
25 m
-
100 m @ 1600%
-
128
-3.449°
-25.016°
0.3 m
100 m
YES
25 m
-
100 m @ 1600%
-