15
-
2.2.3
Connector Use
Connection
Disconnection
· Turn off the power source
· Align the red dots on the connector shells
· Push the plug straight into the socket
· Turn off the power source
· Pull the release sleeve on the male connector to its outermost position and hold there
· Pull the plug from the socket
NOTE
· DO NOT attempt to force open a connection by pulling on the cables or the shells, or by twisting the connectors in any way. Doing so can
loosen the connectors' shells, or even damage the contacts.
· In case a connector's shell is accidentally pulled off, stop using the connector and contact Hesai technical support.
· DO NOT attempt to assemble the connector's shell and cable collet; DO NOT connect a connector without its shell. Doing so may damage the
LiDAR's circuits.
Figure 2.6 Lemo Connection/Disconnection
Before disconnection:
Pull the release sleeve to its outermost
position and hold there
Before connection:
Align the red dots