27
-
■
Functional Safety
Functional Safety: 17 bytes
Field
Bytes
Description
FS Version
1
Version number of the functional safety module (currently 0x00)
Lidar State
1
[7:5] is the LiDAR's current state, see table below
Fault Code Type
[4:3] is the type of the fault code in this data packet
b-01: current fault b-10: past fault
Rolling Counter
[2:0] indicates whether the fault reporting system gets stuck
Starting from 0, the rolling counter increments by 1 every time the fault message is updated
Normally, the fault message is updated every 5 ms
Total Fault Code Num
1
[7:4] counts the total number of fault codes in this queue
Fault Code ID
[3:0] is the sequence number of the fault code in this queue, starting from 1
Fault Code
2
Fault code sent by this data packet
Reserved
8
-
CRC 2
4
CRC-32 checksum of Functional Safety (from the Lidar State field to the Fault Code field)
Lidar State field
LiDAR State
Definition
d-0 (b-000)
Init
Initiating the system. Configuration in progress.
d-1 (b-001)
Normal
In operation. No fault detected.
d-2 (b-010)
Report Failure
Non-safety-related fault(s) detected. Record the fault code(s).
d-3 (b-011)
Pre-Performance Degradation
Warning state: safety-related fault(s) detected; will transition to Performance
Degradation.
d-4 (b-100)
Performance Degradation
Safety-related fault(s) detected. Operating below normal performance.
d-5 (b-101)
Pre-Shutdown
Warning state: significant fault(s) detected; will transition to Shutdown.
d-6 (b-110)
Shutdown
Significant fault(s) detected. Laser emission, motor rotation, and point cloud data
output have stopped; communication remains.
Содержание Pandar128
Страница 1: ...www hesaitech com Pandar128 128 Channel Mechanical LiDAR User Manual HESAI Wechat...
Страница 10: ...8 2 Setup 2 1 Mechanical Installation Figure 2 1 Front View Unit mm...
Страница 11: ...9 Figure 2 2 Bottom View Unit mm...
Страница 12: ...10 Quick Installation Figure 2 3 Quick Installation...
Страница 13: ...11 Stable Installation Figure 2 4 Stable Installation...
Страница 51: ...49 4 6 Monitor The LiDAR s input current voltage and power consumption are displayed...