LFM 4x Reader Rev1.4
back to the table of contents
51
Customer manual
LFM 4x Reader
RFID
WE GENERATE SOLUTIONS
10.4.5 F
– Query parameter
The command „F“ can be used to query the value of a public parameter of the device.
Host
LF Device
CMD
Reader-ID
Parameter No.
F
1 Byte
1 Byte
Device
Host
CMD
Reader-ID
Parameter No.
Parameter Value
f
1 Byte
1 Byte
2 Bytes
The reader sends an individual protocol packet for the requested public parameter.
The values returned in the response for the data elements parameter number and parameter
value are each hexadecimal values (0-F or 00-FF).
In the case of two-digit hexadecimal parameter numbers (Parameter
No.), the parameter number and the parameter value double-digit
hexadecimal are also used in the response.