back to the table of contents
82
Value of the reader parameter.
The values are displayed as decimal values, see
Where used
S2F14, S2F15
Plant model number (Hardware version)
Where used
S1F2
Material Format Code
20:
The material port number corresponds to the sensor number and the sensor status.
Where used
S3F5, S3F7
The data element MHED consists of the head of the SECS message block associated with the defective
message block.
Where used
S9F1, S9F3, S9F5, S9F9
Material ID, predefined area on the transponder in which the unique identifier of the cassette / box is
stored. Depending on the type of transponder, the length of the MID can be changed.
Multipage-Transponder:
The MID length can be set from
„0“ (no MID) to „10“ (MID occupies
the first 10 pages).
Read-Write-Transponder:
The MID corresponds to the DATA (writable) Read-Only-
Transponder:
The MID corresponds to the DATA (fixed)
Where used
S18F10, S18F11
Please note the parameters 42-45
ECV
Format: U1
MDLN
Format: A[6]
MF
Format: B[1]
MHEAD
Format: B[10]
MID
Format: A