Customer manual
LFM 4x Reader
RFID
WE GENERATE SOLUTIONS
HERMOS AG
Gartenstraße 19 • 95490 Mistelgau
Phone: +49 9279 991 - 0
LFM 4x Reader Rev1.3
back to the table of contents
90
S2F15: NEW EQUIPMENT CONSTANT SENT (host -> reading device, reply)
The host changes a reading device attribute (parameter).
S2F15 W
<L[1]
<L[2]
<U1[1] ECID>
<U1[1] ECV>
S2F16: NEW EQUIPMENT CONSTANT ACKNOWLEDGE (reading device ->host)
The reading device acknowledges the reading device parameter).
S2F16
<B[1] EAC>
S2F19: RESET SENT (host -> reading device, reply)
The host transmits a request to the reading device to reset the hardware and software.
If a heartbeat time (parameter 9) is set, the reading device transmits a S1F1 message once the
reset operation is complete.
A power-up reset takes a few seconds.
S2F19 W
<B[1] RIC>
S2F20: RESET ACKNOWLEDGE (reading device -> host)
The reading device acknowledges the reset.
This message is only displayed if a software reset (RIC=2) has been triggered.
S2F20
<B[1] RAC>