26
11.18.1
FORCED DIRECTIONAL AXLES
– INFORMATION / MOUNTING / REGULATION
PM: MANUAL PUMP
V1 e V2: VALVES
A1 e A2: ACCUMULATORS
M1 e M2: MANOMETERS
d
d
– Distance between the towing eye and the hydraulic cylinder: Axles AMB and ADR:
d=250mm
/ Axles FAD:
d=200mm
“ The forced hydraulic cylinder is connected from the drawbar to tractor, and is responsible to actuate the hydraulic
system which guide the directional axle. The coupling of the cylinder should be made with the wheels of the trailer / semi-
trailer fully aligned and the
cylinder should be positioned at half stroke.
The coupling distance
d
between the towing eye and the forced cylinder depends on the brand of the directional axle. To
the system works properly, the marked distances must be respected. This coupling depends of the tractor’s configuration
and his fixation components. There before it should be made to avoid
collision between the two devices when they articulate."
Check and adjust the hydraulic system occasionally!
- The system is regulated in factory, however it should be
checked and adjusted occasionally.
1º - Align the semi-trailer wheels;
2º - Open the valves and verify the pressure level.
- If the semi-trailer is equipped with AMB or ADR axles,
verify if the pressure value is inferior to 50bar. Use the
manual pump to pressurize the system up to 50Bar.
Confirm the pressure in the manometer.
- If the semi-trailer is equipped with FAD axle, verify if the
pressure value is inferior to 80bar. Use the manual pump
to pressurize the system up to 80bar. Confirm the
pressure in the manometer.
3º - Reached 80bar / 50bar, close the valves.
4º - Test the system before initiate the work.