User manual UV Flash Dry
UV Flash Dry
UV Flash Dry
UV Flash Dry 15/700
15/700
15/700
15/700
40
HENSEL-VISIT GmbH & Co. KG
Error search tables
Error search tables
Error search tables
Error search tables
System does not function at all
System does not function at all
System does not function at all
System does not function at all
1
Is the equipment
plugged in?
NO Plug it in correctly.
Continue
with 2
YES
2
Is the power switch on
the trolley switched
ON?
NO
Set power switch to
ON
Continue
with 3
YES
3
FI (RCD) switch on
trolley set to ON?
NO Set FI (RCD) switch
to ON
Continue
with 4
YES
4
Is the power switch on
generator lit and set to
ON?
NO
Switch on power
switch on generator
Continue
with 5
YES
5
Is the ON lamp on the
flash head lit?
NO
System does not
function. Call
customer service.
YES
System works