9
Safety
Safety
Safety
Safety system of the device
system of the device
system of the device
system of the device
The flash system has a safety switch that prevents that high voltage is
carried to the flash tube electrodes when the system is in stand-by mode.
High voltage can only be found at the two electrodes when flashes are
triggered by simultaneously pressing the green START buttons.
The flash head is equipped with an automatic dump mechanism that is
also triggered when the device is disconnected from the power supply or
switched off. It takes approximately 30 s. from the time the device is
switched off or disconnected until the capacitors are safely discharged
below 80 V. The device must not be opened during this time span.