Model OFG- 391
4-2. ERROR CODES
In the event of a control system failure, the digital display will show
an Error Message. These messages are coded: “E-4”, “E-5”,
“E-6”, “E-10”, “E-15”, “E-20 A-D”, “E41”, “E-46”, “E-47”,
“E-48”, E-70B, E-92. A constant tone is heard when an error
code is displayed, and to silence this tone, press any of the product
buttons.
DISPLAY
CAUSE
PANEL BOARD CORRECTION
“E-4”
Control board
Turn switch to OFF position, then turn switch back to ON;
overheating
if display still shows “E-4”, the board is getting too hot; check
for signs of overheating behind the control panel; once panel
cools down the controls should return to normal; if “E-4”
persists, replace the control
“E-5”
Shortening
Turn switch to OFF position, then back to ON; if display
overheating
shows “E-5”, the heating circuits and temperature probe should
be checked; once the unit cools down, the controls should
return to normal; if “E-5” persists, replace the control
“E6-A”
Temperature
Turn switch to OFF position, then turn switch back to ON;
probe open
if display shows “E6”, have the temperature probe checked
“E6-B”
Temperature
Turn switch to OFF position, then turn switch back to ON;
probe shorted
if display shows “E6” have the temperature probe checked
“E-10”
High limit
Reset the high limit by manually pushing up on the red reset
button; if the high limit does not reset, the high limit must be
replaced; call Henny Penny’s Service Department
“E-15”
Drain switch
Close the drain, using the drain valve handle. If display still
shows “E-15”, check drain microswitch per Technical Manual
“E-20 A”
Air pressure switch
Press the timer button to try the ignition process again, and if
failure (stuck closed)
“E-20 A” persists, call Henny Penny’s Service Department
“E-20 B”
Draft fan or
Press the Timer button to try the ignition process again, and if
air pressure
“E-20 B” persists, call Henny Penny’s Service Department
switch failure
(stuck open)
“E-20 C”
Ignition module
Press the Timer button to try the ignition process again, and if
failure
“E-20 C” persists, call Henny Penny’s Service Department
“E20 D”
Modules working
Press the Timer button to try the ignition process again, and if
but no ignition
“E-20 D” persists, call Henny Penny’s Service Department
4-2
703
Содержание OFG-391
Страница 1: ...OPERATOR S MANUAL Henny Penny Open Fryer Gas Model OFG 391...
Страница 2: ......
Страница 12: ...Model OFG 391 OptionalRampUnloading 2 3 703...
Страница 13: ...Model OFG 391 908 2 4...
Страница 17: ...Model OFG 391 403 2 8...
Страница 25: ...Model OFG 391 403 3 5 14 1 2 3 4 5 6 7 8 9 13 11 12 10 Figure 3 2...