Model OFG- 391
3-4. CLOCK SET
14.
Press and “CS-6, CLOCK MODE” shows in the
(Continued)
display, along with “1.AM/PM”.
“1.AM/PM” is 12 hour time, “2.24-HR” is 24 hour
time. Press to change.
15.
Press and “CS-7, DAYLIGHT SAVINGS ADJ”
shows in the display, along with “2.US”.
Press to change to the following:
a. “1.OFF” = No automatic adjustments for daylight
savings time.
b. “2.US” = Automatically applies United States
daylight savings time adjustment. DST activated
on the first Sunday in April. DST de-activated on
the last Sunday in October.
c. “3.EURO” = Automatically applies European (CE)
daylight saving time adjustment. DST activated
on the last Sunday in March. DST de-activated on
the last Sunday in October.
16.
Press and “CS-8, BEGIN NEW DAY” shows in
display, along with “3:00AM”.
This setting indicates the time of day that statistics start
accumulating for a new day. If set to 3:00AM, for
example, then late night cook cycles and filter
operations from midnight to 3:00AM Tuesday morning,
are accumulated with Monday’s statistics.
The CS-8 value can be set from 12:00AM (midnight) to
8:00AM, in half hour increments (12:00 AM,
12:30 AM, 1:00 AM, 1:30 AM, etc.). The default value
for general market software is 3:00 AM.
Press to change the time the “new” day starts.
17.
Clock Set is now complete. Press and hold to exit.
403
3-7
Содержание OFG-391
Страница 1: ...OPERATOR S MANUAL Henny Penny Open Fryer Gas Model OFG 391...
Страница 2: ......
Страница 12: ...Model OFG 391 OptionalRampUnloading 2 3 703...
Страница 13: ...Model OFG 391 908 2 4...
Страница 17: ...Model OFG 391 403 2 8...
Страница 25: ...Model OFG 391 403 3 5 14 1 2 3 4 5 6 7 8 9 13 11 12 10 Figure 3 2...