Model MPC-1L, MPC-22, MPC-554
2-2
Oct. 2018
FM06-038-B
2-4. PROGRAMMING
DESCRIPTIONS
Description
Action
1. °F/°C
Press the
UP/DOWN
button to toggle the mode.
2. Int/USA
Press the
UP/DOWN
button to toggle between International and
Domestic Unit.
3. Unit Type
(554/222/21L/22/1L)
Press the
UP/DOWN
button to toggle between the Unit Types.
4. Set point for top heater
Press the
UP/DOWN
button to increment/decrement the set point value.
5. Set point for bottom heater Press the
UP/DOWN
button to increment/decrement the set point value.
6. Set point for side heater
Press the
UP/DOWN
button to increment/decrement the set point value.
7. CPU temperature
Press
UP/DOWN
button to view highest board temperature.
The actual board temperature displays.
8. Outputs test
1. Use the
DOWN
button to toggle the heat outputs on/off.
2. Use the
UP
button to move on to the next step.
3. Use the
DOWN
button to toggle each of the other three heaters ON/
OFF.
4. Use the
UP
button to advance to the next step.
The display will show which heater is being tested as follows:
OP-
1
, top heater.
OP-2
, bottom heater.
OP-3
, side heater.
“
OP-0
” displays with no heater outputs on and “
OP-A
” displays
when all the heater outputs are on.
9. Initialization
“
InI
” displays.
1. Press and hold the
UP/DOWN
button to initialize the control back to
defaults.
The display counts down “
In-3
”, “
In-2
”,
In-1
”, and then “
InI
”, “
SyS
”, “
donE
”.
2. Release
UP/DOWN
when “
InI
”, “
SyS
” displays.
Control is now initialized.
3.
Wait 2 seconds before turning off power after initialization.
Always press the P button to advance to the next step.
Press and hold the P button at any time to exit Special Programming mode.