![Henny Penny EEG-16X Скачать руководство пользователя страница 90](http://html1.mh-extra.com/html/henny-penny/eeg-16x/eeg-16x_operators-manual_2124320090.webp)
80
Display
Cause
Panel Board Correction
“E-18C”
Both level sen-
sors open.
“E-20A”
“FAN SEN-
SOR
STUCK
CLOSED”
Pressure switch
failure.
If fan is not running, have pressure switch checked;
should be open circuit if no air pressure.
Wiring problem.
If fan is running, wiring error, or relay on I/O board closed
I/O board failure.
“E-20B”
“NO
DRAFT”
“CHECK
FAN”
Pressure switch
failure/hose
loose.
Press power button to vat off and back on again, if E-20-B
persists, have pressure switch checked; should be open
circuit if no air pressure; make sure hose is connected to
fan and pressure switch.
Draft fan failure/
low voltage.
Have draft fan checked; low voltage going to fan.
Flue or hood
obstruction.
Check the fryer flue and hood system for obstructions.
“E-20D"
“IGNITION
FAILURE”
Failure to ignite/
no flame sense.
Press power button to vat off and back on again, if E-20-D
persists, check gas line connections; check gas shut-off
valve; have ignition module checked; gas valve checked;
flame sensor gap checked; gas valve and ignition module
wiring checked.
“E-21”
Slow heat
recovery.
Have a certified service technician check the fryer for cor-
rect voltage to the unit; have heat circuit checked; have
unit checked for loose or burnt wires.
“E-22”
”NO HEAT”
”CHECK
PWR
CORD
AND
BREAKER”
Elements not
heating.
Have power cord and heat circuit checked.
“E-41”
”E-46”
Programming
failure.
Turn power switch to OFF, then back to ON; if display
shows an error code, have the controls re-initialized; if er-
ror code persists, have the control board replaced.
“E-47”
Analog converter
chip or 12-volt
supply failure.
Turn power switch OFF, then back to ON; if “E-47” per-
sists, have the I/O board, or the PC board replaced; if
speaker tones are quiet, probably I/O board failure; have
the I/O board replaced.
“E-48”
Input system
error.
Have PC board replaced.
“E-54C”
Temperature in-
put error.
Turn power switch to OFF, then back to ON; have control
PC board replaced if “E-54C” persists.
Содержание EEG-16X
Страница 2: ......
Страница 10: ...Preface viii...
Страница 12: ...Introduction 2...
Страница 22: ...Installation 12 Figure 2 3 2 Well Dimensions Figure 2 4 3 Well Dimensions...
Страница 23: ...Installation 13 Figure 2 5 4 Well Dimensions...
Страница 24: ...Installation 14...
Страница 66: ...Operation 56...
Страница 72: ...Information Mode 62...
Страница 76: ...Product Program Mode 66...
Страница 92: ...Troubleshooting 82...
Страница 93: ...blank page...