Henny Penny EEG-16X Скачать руководство пользователя страница 80

Level

2

Programming

70

Menu Step

Description

down to the idle set-point temperature. Press the right arrow and “SP-
7C” “IDLE SETPT” flashes in the left display. Press the up or down ar-
row, or use the product buttons, to set idle temperature 200°F to 375°F
(93°C to 191°C).

SP-8 Filter
Tracking Mode

Filter Tracking signals the operator when the oil needs filtering by count-
ing the number of Cook Cycles between filters.
Press and release the right arrow until “SP-8” “FILTER TRACKING
MODE” shows in the display. Use the up or down arrow to choose either
“1.MIXED” filter tracking or “2.GLOBAL”.
NOTE:

GLOBAL means all the products have the same number of cook
cycles between filters

MIXED means each product may be set with different number of
cook cycles between filters. The controls add the cycle count (see
example below) and when the counts equal 1 or greater, filtering is
suggested. Ex., 1 load of fish. 2 loads of french fries, a load of
chicken equals 1. 1/2 + 1/8 + 1/8 + 1/4 = 1

Product

No. Cook Cycles

Cycle Count

Fish

2

1/2

French Fries

8

1/8

Chicken

4

1/4

M

MIIX

XE

ED

D

If MIXED is selected, press the right arrow and SP-8A” “SUGGEST FIL-
TER AT...” shows in the left display, and a value between 75% and 100
% shows on the right display. Press the up or down arrow to change this
value. The lower the value, the sooner the control recommends to filter.
Ex: If set to 75%, the control suggest filtering after 3/4 of the programmed
cook cycles must be completed before the control suggest filtering. Press
the right arrow and “SP-8B” “LOCKOUT ENABLED?” shows in the left
display. Press the up or down arrow to choose “YES or “NO”. If set to
“YES”, when controls suggest filtering, “FILTER LOCKOUT”/“YOU
*MUST* FILTER NOW”, shows in display; more cook cycles are refused
until vat is filtered. Press the right arrow and “SP-8C” “FILTER LOCK-
OUT AT...” shows in left display and a value between 100% and 250%
shows on right display. Press the up or down arrow to change this value.
The lower the value, the sooner the “lockout” occurs. Ex., If set at 100%,
“lockout” occurs when the cycle count reaches 1 or greater. Set at 200%,
twice as many cycles are counted before “lockout” occurs.
G

GL

LO

OB

BA

AL

L

If GLOBAL is selected, press the right arrow.

S

Sp

plliitt V

Va

att

If unit is a split vat, “SP-8A” “LEFT VAT FILTER CYCLES” shows in
left display, and the number of cook cycles between filters shows on

Содержание EEG-16X

Страница 1: ...05 107G OPERATOR S MANUAL EEG 16X EEG 241 EEG 242 EEG 243 EEG 244 E EV VO OL LU UT TI IO ON N E EL LI IT TE E G Ga as s R Re ed du uc ce ed d O Oiill C Ca ap pa ac ciit ty y O Op pe en n F Fr ry ye er...

Страница 2: ......

Страница 3: ...ting The Fryer 10 2 13 Dimensions 11 Chapter 3 Operation 15 3 1 Operating Components 15 3 2 Set Up Mode 18 3 3 Filling Or Adding Oil 19 3 3 1 Filling Vat From Bulk Oil Supply 20 3 4 Morning Start Up P...

Страница 4: ...ton Stats 53 3 18 2 Filter Button Stats 53 3 19 Preventative Maintenance Schedule 53 3 20 Clean Blower Vents 54 Chapter 4 Information Mode 57 4 1 Information Mode Details 57 4 1 1 1 E Log Error Code L...

Страница 5: ...nce or is safety related the words DANGER WARNING CAUTION or NOTICE are used Their usage is described as follows D DA AN NG GE ER R indicates hazardous situation which if not avoided will result in de...

Страница 6: ...Preface iv Equipotential Ground Symbol Waste Electrical and Electronic Equipment WEEE Symbol Shock Hazard Symbols Hot Surface Symbols...

Страница 7: ...ens of restaurants bakeries hospitals etc but not for the continuous mass production of food such as in a factory setting During use the units airborne A weighted emission sound pressure is below 70 d...

Страница 8: ...l I2L 19 8 KW 67 560 Btu h Natural I2HS 19 8 KW 67 560 Btu h Natural I2E 43 46 45 3 mj m3 0 c 19 8 KW 67 560 Btu h Liquid Propane I3P 19 8 KW 67 560 Btu h Liquid Propane Butane I3 B P 19 8 KW 67 560 B...

Страница 9: ...7 kPa South Africa LPG 2 5 kPa Injector Size Natural I2H 2 08 mm Natural I2E 2 08 mm Liquid Propane I3P 1 30 mm Liquid Propane Butane I3 B P 1 30 mm South Africa NG 2 08 mm South Africa LPG 1 30 mm Th...

Страница 10: ...Preface viii...

Страница 11: ...in order to com ply To continue compliance with these directives this unit must not be disposed as unsorted municipal waste For proper dis posal please contact your nearest Henny Penny distributor 1 1...

Страница 12: ...Introduction 2...

Страница 13: ...s d dr riilllls s o or r s sc cr re ew ws s a as s c co om mp po on ne en nt t d da am ma ag ge e o or r e elle ec ct tr riic ca all s sh ho oc ck k c co ou ulld d r re es su ullt t 2 2 2 2 U Un np pa...

Страница 14: ...earances for servicing and proper operation Choose a location which will provide easy loading and unloading without interfering with the final assembly of food orders Operators have found that frying...

Страница 15: ...ermit efficient removal of the steam exhaust and frying odors Special precaution must be taken in designing an exhaust canopy to avoid interference with the operation of the fryer We recommend you con...

Страница 16: ...iin ng g iit ts s iin nd diiv viid du ua all m ma an nu ua all s sh hu ut to of ff f v va allv ve e d du ur riin ng g a an ny y p pr re es ss su ur re e t te es st tiin ng g o of f t th he e g ga as s...

Страница 17: ...ansmission of strain to the connector as specified in the appliance manufacturer s instructions 3 3 See the illustration on the following page for the proper connection of flexible gas line and cable...

Страница 18: ...s control valve is in the off position Upon initial installation and after moving the unit the piping and fittings should be checked for gas leaks A simple checking method is to turn on the gas and br...

Страница 19: ...b be e e eq qu uiip pp pe ed d w wiit th h a an n e ex xt te er rn na all c ciir rc cu uiit t b br re ea ak ke er r w wh hiic ch h iin nc co or rp po or ra at te es s a a 3 3m mm m d diis sc co on nn...

Страница 20: ...on the controls left or right 4 4 The burner lights and operates in a Melt Cycle until the shortening reaches a preset temperature 5 5 Once the display shows a product selection or a double dashes pre...

Страница 21: ...Installation 11 2 2 1 13 3 D Diim me en ns siio on ns s Figure 2 1 Side Dimensions NOTE Side dimensions are the same for all units Figure 2 2 1 Well Dimensions...

Страница 22: ...Installation 12 Figure 2 3 2 Well Dimensions Figure 2 4 3 Well Dimensions...

Страница 23: ...Installation 13 Figure 2 5 4 Well Dimensions...

Страница 24: ...Installation 14...

Страница 25: ...g Controls Indicators page 15 and described in Table 3 1 Operating Controls Indicators page 16 The operating components are shown in Figure 3 2 Operating Components page 17 and described in Table 3 2...

Страница 26: ...from 250 F to 300 F 121 C to 149 C Used in programming modes used as button to back up to a previous parameter in program and filter modes 6 Filter Button Used to access the filter menu also used for...

Страница 27: ...ress to change dis played product also used for X to indicate no or cancel 14 Right Heat Button Press to turn on and off the heat system for the right vat s on full vats either heat button can be used...

Страница 28: ...up the controls will ask to confirm the settings for the fryer 1 1 When main power switch is turned on OFF shows in both displays Press the heat button on either side and SETUP ENTER CODE shows in dis...

Страница 29: ...ns s w wh he en n p po ou ur riin ng g h ho ot t o oiill iin nt to o v va at t O Oiill a an nd d a allll m me et ta all p pa ar rt ts s t th ha at t a ar re e iin n c co on nt ta ac ct t w wiit th h...

Страница 30: ...OTE MUST be equipped with optional accessories and controls set to YES for BULK OIL SUPPLY in Set Up Mode 1 1 Turn the main power switch to the on position 2 2 Place basket support inside of vat 3 3 P...

Страница 31: ...bypassed if desired by pressing button or X button and holding it for 5 seconds The control then shows EXIT MELT and YES NO Press button for YES and vat heats continuously until the set point temperat...

Страница 32: ...ullt tiin ng g iin n s se ev ve er re e b bu ur rn ns s a an nd d o or r p pr ro op pe er rt ty y d da am ma ag ge e NOTE If desired the melt cycle may be bypassed by pressing and holding the or X bu...

Страница 33: ...nu ua all T To op p O Of ff f If oil level is a little low oil can be added to vat at any time from BIB to raise oil level to the proper level by following steps below This procedure is NOT to be used...

Страница 34: ...JIB IS LOW and an alarm sounds 2 2 Open right door pull JIB from unit pull cap from JIB top discard empty BIB and replace with full one 3 3 1 10 0 M Mo od de ell E EE EG G 2 24 41 1 O Oiill R Re es s...

Страница 35: ...iir r 1 1 Open door and pull reservoir forward 2 2 Slide reservoir to the left and lift from fryer 3 3 Clean reservoir at a sink with soap and water NOTE Before placing the reservoir back into positio...

Страница 36: ...ressed fryer resumes normal operation and control suggests filter later 2 2 Check Filter Pan If the filter drain pan or cover is not in place the display shows CHK PAN Make sure that the filter pipe i...

Страница 37: ...emove the brush immediately to prevent damage to the drain valve and then press the button and DRAINING displays Controls will proceed with filtering process 4 4 At end of drain cycle VAT EMTY followe...

Страница 38: ...g ge e m ma ay y o oc cc cu ur r t to o t th he e d dr ra aiin n v va allv ve e This section describes how to run an automatic filter procedure using the push button feature 1 1 During normal operatio...

Страница 39: ...operation Press X button and pump runs for another 30 seconds You can try to fill the vat 3 times 9 9 After trying to fill the vat 3 times without success the controls then shows CHANGE FILTER PAD YE...

Страница 40: ...e er rs so on na all iin njju ur ry y 1 1 Check Filter Pan A new filter pad should be used on the first filter of each day but the same filter pad can be used the rest of the day except for fish vats...

Страница 41: ...display shows RINSING and vat fills with oil 1 12 2 Once vat is filled OPEN DRAIN shows in display Pull out on drain knob to open the drain and display shows RINSING When rinsing is complete display...

Страница 42: ...lter pipe is tightly connected and that the filter drain pan is as far back under fryer as it will go and the filter pan cover is in place If the filter drain pan or cover is not in place the display...

Страница 43: ...lating it through the filtering system and the display shows 5 00 STOP 1 15 5 Once oil is polished display shows FILL VAT along with YES Press button the display shows FILLING and vat fills with oil 1...

Страница 44: ...lease right arrow button twice until display shows 3 DISPOSE Press button and display shows DISPOSE YES NO 4 4 Press button and IS DISPOSAL UNIT IN PLACE YES NO shows in display 5 5 With discard shutt...

Страница 45: ...NO If control suspects oil in drain pan CAUTION IS THERE OIL IN PAN YES NO may show in display Make sure drain pan is empty before proceeding 4 4 Press button and display shows IS DISPOSAL UNIT IN PL...

Страница 46: ...from vat into drain pan 6 6 Display shows VAT EMTY YES NO Verify that vat is empty and press button 7 7 Display shows CLEAR OLD OIL FROM OIL LINES PUMP X DONE Press and hold button for a few seconds t...

Страница 47: ...ho ot t o oiill D Do o n no ot t o ov ve er rf fiillll S Sh hu ut tt tlle e h ho olld ds s o oiill f fr ro om m o on ne e f fu ullll s siiz ze e f fr ry y p po ot t o or r t tw wo o s sp plliit t v v...

Страница 48: ...n 38 2 2 Release cover latch and hinge back cover on oil disposal shuttle Ensure crumb catcher is in place 3 3 Roll oil disposal shuttle under fryer until it stops Ensure drain aligns with opening in...

Страница 49: ...button and display shows DISPOSE YES NO If control suspects oil in drain pan CAUTION IS THERE OIL IN PAN YES NO may show in display Make sure drain pan is empty before proceeding 6 6 Press button and...

Страница 50: ...t tiin ng g s sh hu ut tt tlle e t to o t th he e d diis sp po os sa all a ar re ea a 1 12 2 Remove the oil disposal shuttle from under fryer and replace with the filter pan assembly 1 13 3 Close and...

Страница 51: ...ghten the handle 3 3 1 14 4 C Ch ha an ng giin ng g T Th he e F Fiillt te er r P Pa ad d In order to assure good oil pumping performance the filter pad or paper should be changed at least once per day...

Страница 52: ...ov ve e o or r s se ev ve er re e b bu ur rn ns s c co ou ulld d r re es su ullt t I If f t th he e f fiillt te er r p pa an n iis s m mo ov ve ed d w wh hiille e f fu ullll o of f o oiill u us se e...

Страница 53: ...ing ring and clean thoroughly with soap and water Rinse thoroughly with hot water 6 6 Pull the filter pad from the pan and discard pad 7 7 Remove the bottom screen from pan and clean thoroughly with s...

Страница 54: ...pad into pan as water will dissolve the filter pad 9 9 Reassemble in reverse order placing the bottom screen into the filter pan first followed by the filter pad retaining ring and the crumb catcher...

Страница 55: ...ro ot te ec ct tiiv ve e g gllo ov ve es s w wh he en n r re em mo ov viin ng g t th he e b ba as sk ke et t r re es st t T Th he e b ba as sk ke et t r re es st t m ma ay y b be e h ho ot t a an nd d...

Страница 56: ...t tiio on n w wiit th h y yo ou ur r e ey ye es s o or r s sk kiin ns s S Se ev ve er re e b bu ur rn ns s m ma ay y r re es su ullt t C Ca ar re ef fu ulllly y r re ea ad d iin ns st tr ru uc ct tiio...

Страница 57: ...keep solution 1 in 25 mm above the top fill line 1 10 0 Using the open fryer brush never use steel wool scrub the inside of the vat At the end of the one hour display shows CLN DONE and beeps Press b...

Страница 58: ...drain into drain pan Rinse at least 3 times but be careful not to overfill the drain pan Display now shows RINSE COMPLETE YES NO 1 17 7 Once vat is completely rinsed press the button and display shows...

Страница 59: ...ullt t C Ca ar re ef fu ulllly y r re ea ad d iin ns st tr ru uc ct tiio on ns s o on n t th he e c clle ea an ne er r I If f s so ollu ut tiio on n c co om me es s iin n c co on nt ta ac ct t w wiit...

Страница 60: ...end of the one hour display shows CLN DONE and beeps Press button and display shows REMOVE SOLUTION FROM VAT B BU UR RN N R RI IS SK K T To o a av vo oiid d b bu ur rn ns s w wh he en n p po ou ur rii...

Страница 61: ...is closed M Ma ak ke e s su ur re e t th he e iin ns siid de e o of f t th he e v va at t t th he e d dr ra aiin n v va allv ve e o op pe en niin ng g a an nd d a allll t th he e p pa ar rt ts s t th...

Страница 62: ...for any cracks or breaks and replace if necessary 3 3 To replace O ring use a small flat bladed screwdriver pry up on the O ring and pull off of end of tube Roll new O ring into notch on tube Before p...

Страница 63: ...aining Before Filtering Press either filter button 1 time The left display shows COOKS RE MAINING and the right display shows the number of cook cycles before the next auto filter For example REMAININ...

Страница 64: ...ers and blower vents twice a year 1 1 Press the main power switch to the off position 2 2 Unplug power cord and turn gas shut off handle clockwise to turn off the gas and then disconnect the gas line...

Страница 65: ...the vent slots on the inside of rear panel and then replace panel 8 8 Reattach the gas line and turn the shut off handle counter clockwise to turn on the gas and reconnect the cable restraint to the f...

Страница 66: ...Operation 56...

Страница 67: ...scussed in this section To ensure proper operation of fryer please consult Henny Penny Corp before changing any of these settings For more information on these functions contact Technical Support at 1...

Страница 68: ...ook data and the LED flashes 3 3 Press the down arrow button to start viewing the cook data For example if the left timer 1 LED is flashing PRODUCT FRY L1 shows in displays If the right timer 2 LED is...

Страница 69: ...il discarded L R DISPOSE TUE 0 Oil temperature recovery time L R RECOVERY TUE 1 45 Total number of cook cycles that day L R TOT CK TUE 38 Number of cycles stopped before DONE QUIT CK TUE 2 Cook Cycles...

Страница 70: ...Ex OIL 4 14 DAYS Press product button 2 to view 3rd oldest oil data Ex OIL 3 12 DAYS Press product button 3 to view 2nd oldest oil data Ex OIL 2 15 DAYS Press product button 4 to view previous batch o...

Страница 71: ...out all the usage information RESET USAGE ENTER CODE 4 4 1 1 6 6 1 16 6 U US SB B S Su up pp po or rt t 1 1 Press the down arrow button and display shows REPORTS type of report PRINT This will print t...

Страница 72: ...Information Mode 62...

Страница 73: ...du uc ct t N Na am me es s 3 3 Use the up and down buttons to scroll through the 40 products or press the desired product button 4 4 Press the right arrow button and NAME shows in the left display an...

Страница 74: ...and an alarm time in the right display Press the product buttons or the up and down arrow buttons to set an alarm Ex If a Cook Cycle was set at 3 minutes and an alarm was to go off after 30 seconds i...

Страница 75: ...down at temperatures below this setting Press the product button or the up and down arrow buttons to change this value F Fu ullll H He ea at t 1 15 5 Press the right arrow button until FULL HT shows...

Страница 76: ...Product Program Mode 66...

Страница 77: ...2 2 Enter code 1 2 3 and SP 1 TEMP FORMAT show in the displays NOTE If a bad code is entered a tone sounds and BAD CODE shows on the display Wait a few seconds the controls revert back to the cook mod...

Страница 78: ...SP 11 Clean Out Time XX MIN SP 12 Clean Out Temperature XXX F or C SP 13 Cooking User IO After Cook Cycle display shows previous menu item or SP 14 Number of Baskets 2 BASKETS or 4 BASKETS SP 15 Show...

Страница 79: ...iet SP 5 Audio Tone Press and release the right arrow until SP 5 TONE flashes in the left display Press the up or down arrow or product buttons to adjust the tone of the speaker 2000 being the maximum...

Страница 80: ...D is selected press the right arrow and SP 8A SUGGEST FIL TER AT shows in the left display and a value between 75 and 100 shows on the right display Press the up or down arrow to change this value The...

Страница 81: ...display Press the up or down arrow to choose YES or NO If set to YES press the right arrow and the left display shows SP 8C FULL VAT LOCKOUT CYCLES and the number of cook cycles before filter lockout...

Страница 82: ...twice during normal opera tion One volume setting shows in the left display NONE to 10 10 being the loudest and the seconds volume shows in the right display To select the volume press button under t...

Страница 83: ...NGED shows in display If not satisfied with code press the info button and CAN CEL shows in display then reverts back to SP 25 CHANGE MGR CODE 1 YES Now the above steps can be repeated SP 26 Usage Cod...

Страница 84: ...be programmed A time period may be anywhere from 1 to 180 minutes in length 1 1 Press and hold the program button for 5 seconds until LEVEL 2 SP PROG ENTER CODE shows in the display 2 2 Press the prog...

Страница 85: ...d CS 2 ENTER TIME flashes in the left display and the time flashes in the right display Press the up and down arrow buttons or product buttons to change the time 6 6 Press the right arrow button and C...

Страница 86: ...h S St ta at t F Fiillt te er r C Co on nt tr ro oll M Mo od de es s The Data Logging Heat Control Tech Stat and Filter Control Modes are advanced diagnostic and program modes mainly for Henny Penny u...

Страница 87: ...temperature too hihg Let unit cool down 15 20 minutes push up on metal reset button under right side of the controls if high limit does not reset high limit must be replaced Vat is under filled BIB is...

Страница 88: ...cess Filter pan not com pletely engaged Make sure filter pan return line is pushed completely in to the receiver on the fryer Filter pan clogged Clean pan and change paper or pad Damaged O ring on fil...

Страница 89: ...on then back to ON if display shows E 5 the heating circuits and temperature probe should be checked E 6A Temperature probe open Turn switch to OFF position then back to ON if the dis play shows E 6 t...

Страница 90: ...persists check gas line connections check gas shut off valve have ignition module checked gas valve checked flame sensor gap checked gas valve and ignition module wiring checked E 21 Slow heat recover...

Страница 91: ...itch interlock position E 83 A Pressure too high Check filter system in Vat 1 E 83 B Pressure too high Check filter system in Vat 2 E 83 C Pressure too high Check filter system in Vat 3 E 83 D Pressur...

Страница 92: ...Troubleshooting 82...

Страница 93: ...blank page...

Страница 94: ...yp pe en nn ny y c co om m I In ns siid de e t th he e U U S S 1 1 8 80 00 0 4 41 17 7 8 84 40 05 5 t te ec ch hn niic ca alls se er rv viic ce es s h he en nn ny yp pe en nn ny y c co om m O Ou ut t...

Отзывы: