Menu Step
Description
down to the idle set-point temperature. Press the right arrow and “SP-
7C” “IDLE SETPT” flashes in the left display. Press the up or down ar-
row, or use the product buttons, to set idle temperature 200°F to 375°F
(93°C to 191°C).
SP-8 Filter
Tracking Mode
Filter Tracking signals the operator when the oil needs filtering by count-
ing the number of Cook Cycles between filters.
Press and release the right arrow until “SP-8” “FILTER TRACKING
MODE” shows in the display. Use the up or down arrow to choose either
“1.MIXED” filter tracking or “2.GLOBAL”.
NOTE:
•
GLOBAL means all the products have the same number of cook
cycles between filters
•
MIXED means each product may be set with different number of
cook cycles between filters. The controls add the cycle count (see
example below) and when the counts equal 1 or greater, filtering is
suggested. Ex., 1 load of fish. 2 loads of french fries, a load of
chicken equals 1. 1/2 + 1/8 + 1/8 + 1/4 = 1
Product
No. Cook Cycles
Cycle Count
Fish
2
1/2
French Fries
8
1/8
Chicken
4
1/4
M
MIIX
XE
ED
D
If MIXED is selected, press the right arrow and SP-8A” “SUGGEST FIL-
TER AT...” shows in the left display, and a value between 75% and 100
% shows on the right display. Press the up or down arrow to change this
value. The lower the value, the sooner the control recommends to filter.
Ex: If set to 75%, the control suggest filtering after 3/4 of the programmed
cook cycles must be completed before the control suggest filtering. Press
the right arrow and “SP-8B” “LOCKOUT ENABLED?” shows in the left
display. Press the up or down arrow to choose “YES or “NO”. If set to
“YES”, when controls suggest filtering, “FILTER LOCKOUT”/“YOU
*MUST* FILTER NOW”, shows in display; more cook cycles are refused
until vat is filtered. Press the right arrow and “SP-8C” “FILTER LOCK-
OUT AT...” shows in left display and a value between 100% and 250%
shows on right display. Press the up or down arrow to change this value.
The lower the value, the sooner the “lockout” occurs. Ex., If set at 100%,
“lockout” occurs when the cycle count reaches 1 or greater. Set at 200%,
twice as many cycles are counted before “lockout” occurs.
G
GL
LO
OB
BA
AL
L
If GLOBAL is selected, press the right arrow.
•
S
Sp
plliitt V
Va
att
If unit is a split vat, “SP-8A” “LEFT VAT FILTER CYCLES” shows in
left display, and the number of cook cycles between filters shows on
Содержание EEG-16X
Страница 2: ......
Страница 10: ...Preface viii...
Страница 12: ...Introduction 2...
Страница 22: ...Installation 12 Figure 2 3 2 Well Dimensions Figure 2 4 3 Well Dimensions...
Страница 23: ...Installation 13 Figure 2 5 4 Well Dimensions...
Страница 24: ...Installation 14...
Страница 66: ...Operation 56...
Страница 72: ...Information Mode 62...
Страница 76: ...Product Program Mode 66...
Страница 92: ...Troubleshooting 82...
Страница 93: ...blank page...