F
ace Plate
Use and maintenance manual
3.
Move the distance gauge pusher in line with the
Face Plate
and press
CALIBRATION COMPLETE
▪
Return the gauge to
home
position.
▪
The wheel balancer is ready for operation.
In the event of errors or faulty operation, the writing
“
r.P.
”
:
ap
pears on the display : shift the gauge to the
Home
position and repeat the calibration operation exactly as described above. If the error persists, contact the
Technical
Service Department. In the event of incorrect input in the rim distance gauge calibration function, press
to cancel it.
Diameter gauge calibration
E
1. Display the diameter gauge CALIBRATION function from the SETUP menu
2.
Place the gauge rod on the
spindle shell
as shown in the figure and press
Important: Always read and follow the instructions.
•
19
Gauge Rod touches the
Spindle Shell here
.
.