3 Technical Data
3.1 Technical Data
Storage temperature
-5°C to +60°C (+23°F to +140°F),
dry, dust-free
Operating temperature
+10°C to +40°C (+50°F to +104°F)
Relative humidity
20% - 80% non-condensing
Power supply
110 – 240V AC 50/60 Hz, 100 W
Compressed air supply
min. 4 bar (72 PSI), max. 6 bar (116 PSI)
Quality
If the required quality is not achieved, install a
LOCTITE
®
97120 filter regulator
filtered 10 µm, oil-free, non-condensing
Accessory order no. 88649
Pneumatic hose, control air connection
O.D.
6 mm
Pneumatic hose, reservoir connection
O.D.
6 mm
Weight
~ 2.3 kg
3.2 Dimensions
4 Installation
4.1 Environmental and Operating Conditions
– Typically, the compressed air hose should not be longer than 2 m
– Do not bend compressed air hoses.
– Tighten all connections carefully.
– Only for use indoors and not in explosive environments.
– Only for use in dry rooms without any particular sources of dust.
4.2 Connecting
Attention!
The device should be switched off while the electrical supply to the rotor pump
"Pump" is connected and disconnected.
The product feed must be completely depressurized before any screw connections are opened.
+0.05
-0.10
+0.05
-0.10
~ 150 mm
~ 6
"
~ 270 mm
~ 10.6
"
~
2
3
0
mm
~
9
"
Freiraum
ca. 150 mm
Clearance
ca. 6 inch
EQ RC15 Pump Controller