35
1 Please observe the following
1.3 For your safety
Please refer to the relevant Technical Data Sheet for the Loctite® product to be processes at
Download from www.loctite.com or request the Technical Data Sheet and the Safety Data Sheet
from your Henkel Technical Service.
INSTRUCTIONS given in these data sheets must be followed scrupulously at all times!
While under warranty, the unit may be repaired by an authorized Henkel service representative
only.
Warning!
Improper handling of chemicals may result in potential health hazards!
Observe general safety regulations 30for the30 handling of chemicals!
Follow the manufacturer’s instructions! Request a safety data sheet 30for the30 Loctite
®
product
to be processed!
Only non-flammable cleaning agents are allowed!
Always wear goggles when working with compressed air!
Damage to the power cord or the housing 30of the power adapter can result in contact with live
electrical parts.
Check the power cord and the unit before each use.
Never operate the system if the power supply unit/power cord is damaged! Replace a damaged
power supply unit/power cord with a new one.
Ensure
power supply is off
whenever you
connect or disconnect
the connection cord of a
rotor
pump
. Otherwise the drive motor electronics might get damaged.
We cannot be held responsible for damage or injury of any kind because of failure to observe
the instructions in this Operating Manual.
1.4 Field of Application (Intended Use)
The control unit RC15 is used for controlling the volumetric dosing with a compact rotor pump.
The product supply to the pump is done via a Loctite reservoir, which the RC15 controller
provides with regulated compressed air and electrical control signals.
If dosed product needs to be distributed to the cylindrical inside surface of a bore, a rotor spray
can be connected directly.
Limits of parameter adjustment:
Dispense time: 0,5 to 100 seconds
Dispense quantity: 1µl to 4000 µl (4ml)
The flow rate depends on the pump type and the according volume per revolution calibration:
Pump Type:
WWC Number
IDH Order No.
Nominal Calibration
(µl / revolution)
Min. Flow Rate
(µl/min.)
Max. Flow Rate
(µl/min.)
Compact Rotor
Dispenser 1.0
97621
1654036
12,5
10
1400
Compact Rotor
Dispenser 4.0
97611
1196160
50
30
5800