43
2 Description
7
Display of the current program
Up to 3 dosing programs with different dosing parameters can be stored and selected by
dedicated start signal. The dosing programs can be switched to from the main screen by
touching display field
7
. The associated parameters of each program, [X], [Y] or [Z] can be
shown and modified that way. The parameters in the extended settings menu, such as
the suck back volume and suck back extrusion rate are depending on the programs as
well. Since it is not possible to switch over the programs in the extended settings menu,
this has to be carried out on the main screen. A start signal enables the corresponding
program and displays its settings.
8
Display of the current tank pressure
The tank pressure is displayed and monitored. In the case of significant deviations in the
current value from the stored set up, the device issues an optical and acoustic alarm.
Touching the pressure display field
8
takes over the current pressure as the new setting
and the alarm is canceled.
9
Status symbol for the product supply
Symbol for Reservoir
This symbol shows the current status of the product supply: full, refill, empty, vented or
fault. By touching this symbol, the tank is pressurized and vented.
Symbol for Syringe :
This symbol shows the current status of the product syringe: See section 5.7.
1
2
3
4
5
6
7
8
9