Chapter
4
Peak Look Window
The following example details the peak look window requirement.
Rung 2:3
SETS UP CAM WINDOW FOR TONNAGE MODULE
| PANELVIEW |
| AND CH'S |
| 1&2 MODULE |
| CAM CYCLE |
| BIT |
| +LIM---------------+ N10:21 |
|-+LIMIT TEST +-------------------------------------------------------------------------------------------------( )-----|
| |Low Lim 90| 0 |
| | | |
| |Test N153:0| |
| | 0| |
| |High Lim 220| |
| | | |
| +------------------+ |
- OR –
Rung 2:7
| | |
| prox probe| |
| or rotary | ch's 1&2 |
| cam input | cam bit |
| I:4 N10:21 |
|----] [---------------------------------------------------------------( )-----|
| 0 0 |
Note:
Customer mapped in input.
Input for the Look Window can be obtained from a rotary cam limit switch, proximity probe or position
resolver.
N10:21/1
Indicates the machine stop and start status on the Panel.
This bit is set to 1 (ON) when a module alarm occurs.
N10:21/0
Set bit to 1 (ON) during peak window time, clear at other times.
Page 4-12