Chapter
3
Using RS Logics 500 software, reserve two integer file’s for tonnage monitoring. Reserve one counter for tonnage
monitoring.
For illustration purposes in this manual, we have reserved Integer file N10:0 - N10:25.
Data Description
Address
I
nteger
Channel 1 Trend Deviation in percent
N10:1
Integer
Channel 2 Trend Deviation in percent
N10:2
Integer
Channel 1 Low Trend Alarm Setting
N10:3
Integer
Channel 1 High Trend Alarm Setting
N10:4
Integer
Channel 2 Low Trend Alarm Setting
N10:5
Integer
Channel 2 High Trend Alarm Setting
N10:6
Integer 256 Multiply register N10:7
Integer
Channel 1 Peak Value in Tons
N10:8
Integer
Channel 2 Peak Value in Tons
N10:9
Integer
Channel 1 High Capacity Alarm Setting
N10:11
Integer
Channel 1 Low Capacity Alarm Setting
N10:12
Integer
Channel 2 High Capacity Alarm Setting
N10:13
Integer
Channel 2 Low Capacity Alarm Setting
N10:14
Integer
Scale
N10:15
Bit Channel 1 High Capacity Alarm N10:16/0
Bit
Channel 1 Low Capacity Alarm
N10:16/1
Bit Channel 2 High Capacity Alarm N10:16/2
Bit
Channel 2 Low Capacity Alarm
N10:16/3
Bit Channel 1 High Trend Alarm N10:16/4
Bit Channel 1 Low Trend Alarm N10:16/5
Bit Channel 2 High Trend Alarm N10:16/6
Bit Channel 2 Low Trend Alarm N10:16/7
Bit Learn Cycle Bit N10:16/9
Bit Low Alarm Inhibit Bit N10:16/10
Bit Alarm Indication Bit (Module Alarm Bit) N10:16/11
Integer Low Alarm Inhibit Cycle Count N10:17
Integer # Samples (set from 1 to 16) N10:18
Integer Current Running Sample Counter N10:19
Integer Mode Status Value N10:20
Bit Cam Cycle Bit N10:21/0
Bit Start\Stop Indicator Bit N10:21/1
Bit Reverse Load Bit N10:21/6
Bit Alarm Reset Bit N10:21/7
Integer
Channel 1 Calibration Value
N10:22
Integer
Channel 2 Calibration Value
N10:23
Integer
Channel 1 Sample Peak in Tons
N10:24
Integer
Channel 2 Sample Peak in Tons
N10:25
Page 3-5