Step 7. Set Sample Count
The sample count is a user programmable parameter that tells the processor how many machine strokes are
required to establish sample or benchmark load values. The value can range from 0 to 16. A value of 0
invalidates the Monitor Parts mode. You should set Sample Count to a minimum of 1 to enable Monitor Parts
mode.
Note: Each time you change Monitor Parts mode bit from ON to OFF, the sample value is cleared. During
normal operations, Monitor Parts mode is enabled when beginning a process run. If the process varies due to
change in material thickness, for example, it may be necessary to take a new sample.
Rung 3:34
| | D0 BIT OF |
| PANELVIEW | SAMPLE |
| ENTRY | COUNT |
| | |
| N10:18 O:4 |
|----] [---------------------------------------------------------------------------------------------------------------( )-----|
| 0 8 |
Rung 3:35
| | D1 BIT OF |
| PANELVIEW | SAMPLE |
| ENTRY | COUNT |
| N10:18 O:4 |
|----] [---------------------------------------------------------------------------------------------------------------( )-----|
| 1 9 |
Rung 3:36
| | D2 BIT OF |
| PANELVIEW | SAMPLE |
| ENTRY | COUNT |
| N10:18 O:4 |
|----] [---------------------------------------------------------------------------------------------------------------( )-----|
| 2 10 |
Rung 3:37
| | D3 BIT OF |
| PANELVIEW | SAMPLE |
| ENTRY | COUNT |
| N10:18 O:4 |
|----] [---------------------------------------------------------------------------------------------------------------( )-----|
| 3 11 |
Rung 3:38
| | D4 BIT OF |
| PANELVIEW | SAMPLE |
| ENTRY | COUNT |
| N10:18 O:4 |
|----] [---------------------------------------------------------------------------------------------------------------( )-----|
| 4 12 |
Page 4-5