STEP 4 S – Select the time for the second cycle (which in this example is RINSE) using 

 

or 

 

button.  Press NEXT to go to Step 5S.  Press REGEN to return to the previous step.

STEP 5 S – Set Gallons Capacity using 

 

or 

 button.  If value is set to:

• “oFF” regeneration will be based solely on the day override set (see Installer Display/Settings 

Step 3, page 6 or 

• as a number of gallons (allowable range 20 to 250,000) regeneration will be based on the 

value specified.

Increment increase is 20 for the range 20 to 2000, 100 for the range of 2000 to 10,000 and 

500 for the range of 10,000 to 50,000 and 2000 for range of 50,000 to 1,500,000.

Press NEXT to go to Step 6S.  Press REGEN to return to previous step.

STEP 6 S – Set Regeneration Time Options using the 

 

or 

 button. If value is set to:

• “DELAYED” means regeneration will occur at the preset time;

• “IMMEDIATE” means regeneration will occur immediately when the gallons capacity 

reaches 0 (zero); or

• “D IMMEDIATE” means regeneration will occur at one of the following:

- the preset time when the gallons capacity falls below the reserve or the specified number of 

days between regenerations is reached, whichever comes first; or

- immediately after 10 minutes of no water usage when the gallon capacity reaches 0 (zero).

See page 26 for more options.  Factory Setting is Delayed.  Press NEXT to go to Step 7S.  

Press REGEN to return to previous step.

STEP 7 S – Set Relay to activate by Time, Gallons, Regen Gallons, Lockout, Off or Ser-

vice Alarm by using 

 

or 

 buttons.  A relay can be used to operate a chemical feed pump 

or solenoid, etc.  The choices are:

 • 

 Relay Triggered on Time - Relay activates after set number of minutes after start of regen-

eration.  Start of regeneration is defined by first backwash cycle, dn brine or up brine, 

whichever is first.  Relay deactivates after set time. Press NEXT for programming.

 •  Relay Triggered on Gallons - Relay activates every set number of gallons while in service 

and deactivates after set time.  Press NEXT to go to 11S for programming.

  •  Relay Triggered on Regen Gallons - Relay activates after set number of gallons in service 

or gallons used during regeneration and de-activates after set time or when meter stops 

registering flow, whichever comes first.  Press NEXT to go to 14S for programming.

  •  Service Alarm - Relay activates on service alarm setting: gallons, time or both, see step 16S.

  • Relay Triggered for Lockout - The relay closes at set time before or after the start of 

regeneration, as referenced by start of backwash.  Negative start time delays regenera-

tion by that amount.  Selection of energizing relay for complete regeneration cycle plus 2 

minutes before and after is available by selecting REGEN for time setting, see step 17S.

  •  Off - If off is selected, Steps 7S to 19S will not be shown.  Factory setting = OFF.  

Press NEXT to go to step 20S or other selection screens for relay settings.

STEP 4S

SET 

6:00

MIN

STEP 5S

SET   

OFF

GALLONS CAPACITY

RINSE TIME

STEP 7S

RELAY 1 "TIME"  

TRIGGER

SET   

STEP8S

RELAY 1 SET POINT

10

MIN

RELAY 1 DURATION

3:00

MIN

STEP 9S

SET   

SET   

RELAY 1 "GALLONS" 

TRIGGER

SET   

STEP 10S

STEP 6S

SET   

DELAYED

REGEN

STEP 8 S – 

If off was selected in previous step, this screen does not appear.   

If Time chosen to Activate Relay, use up and down arrows to set # of minutes 

AFTER START OF REGEN to activate relay. Start of regeneration is defined as 

first Backwash or Regenerant Draw mode.  Time Range = 1 – 500 minutes. Press 

NEXT to go to Step 9S.

STEP 9 S – 

Use Up and Down arrows to set duration of relay activation in minutes.  

Time Range is 0:01 (1 second) to 500:00 (500 minutes)  Press NEXT to go to Step 

20S.  Press REGEN to return to previous step.

STEP 10 S – 

Gallons chosen to activate relay. If Off or Time was selected in previous 

steps, this screen does not appear.  Press NEXT for trigger programming.

Содержание ProMate-6.0

Страница 1: ...Owner s Filter Manual Manufactured by HELLENBRAND INC 404 Moravian Valley Road Waunakee Wisconsin 53597 www hellenbrand com info hellenbrand com FILTER SYSTEM 107207 Rev B 5 8 18 2007 2018...

Страница 2: ...assistance for servicing your water filter please contact the dealer who installed this system Job Specification Sheet 2 Pre Installation Check List 3 Installation Instructions 4 Programming 5 Initia...

Страница 3: ...recommended with all electric controls Existing Plumbing Condition of existing plumbing must be free from lime and iron build up Piping that is built up heavily with lime and or iron must be replaced...

Страница 4: ...joints should be cool and solvent cements should be set before installing the nut split ring and o ring Avoid getting primer and solvent cement on any part of the o rings split rings bypass valve or...

Страница 5: ...cally When water is being treated i e water is flowing through the system the word GPM flashes on left side of display when other than flow rate is displayed Figure 8 DAYS TO A REGEN 6 CAPACITY REMAIN...

Страница 6: ...to prevent multiple units from regenerating at the same time Step 5I Regeneration Time minutes Set the minutes of day for regeneration using or buttons This display will not be shown if system is set...

Страница 7: ...vide treated water when the regeneration has been completed Figure 11 STEP 1S STEP 2S FILTERING STEP 3S SET 12 00MIN STEP 1S Press NEXT and simultaneously for 3 seconds If screen in Step 2S does not a...

Страница 8: ...tivates after set time Press NEXT for programming Relay Triggered on Gallons Relay activates every set number of gallons while in service and deactivates after set time Press NEXT to go to 11S for pro...

Страница 9: ...arrows to set duration of relay activation in minutes Range 0 01 1 second 500 00 500 minutes Press NEXT to go to Step 20S Press REGEN to return to previous step STEP 13S If REGEN gallons chosen to act...

Страница 10: ...his display will show dashes if a water meter is not installed Press the NEXT button at any time to go to Step 6 D Press REGEN to return to the previous step DIAGNOSTICS STEP 1D STEP 2D 2 DAYS SINCE R...

Страница 11: ...on at time of stall Press NEXT to exit valve history STEP 1VH VALVE HISTORY STEP 2VH 970 TOTAL DAYS STEP 3VH 235 STEP 4VH 175 GAL x1K RETURN TO NORMAL MODE Can not be reset TOTAL REGENS TOTAL GALLONS...

Страница 12: ...No Hard Water Bypass During Regeneration See instructions in Step 6CS Reclaim Enabled Allows control to operate in Reclamation Mode up to 3 reclaim events can be programmed See instructions in Step 8C...

Страница 13: ...ating MAV will transition back to Service after the completion of the preset duration time labeled Reclaim Duration Three reclaim events are possible Select either Reclaim Enabled Reclaimed 2x for two...

Страница 14: ...to return to previous step Only displays if RECLAIM 2X is selected Use the or buttons to select number of minutes after start of regeneration for Aux MAV to divert waste water Press NEXT to program n...

Страница 15: ...or buttons until selection of fourth cycle appears in left upper corner in this example RINSE is selected Press NEXT to go to Step 18CS Press REGEN to return to previous step STEP 18CS Press the or bu...

Страница 16: ...osen drive cap gear 1 4 turn timed out trying to reach next position C2 Address high drive forces C3 Motor failure during regeneration replace motor Error Code 104 Motor ran too long D1 Piston unable...

Страница 17: ...ce battery if less than 3 volts F Defective PC board F Replace PC board 3 Control does not display correctly A Power outage 2 years A Reset time of day replace lithium coin type battery time of day on...

Страница 18: ...r assembly C Defective relay See figure below C Replace Relay D Defective PC Board D Replace PC Board E Faulty wire connections between E Check and repair wire connections PC board and relay 7 Relay e...

Страница 19: ...6 21 x 62 1 110569 5 Filter Media Contact dealer for filter media type quantity 6 Underbedding Contact dealer for underbedding type quantity Vortech tank does not use underbedding Owners Manual 1 1072...

Страница 20: ...OVER AND DRIVE ASSEMBLY After completing any valve maintenance involving the drive assembly or the drive cap assembly and pistons press and hold NEXT and REGEN buttons for 3 seconds or unplug power so...

Страница 21: ...The nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench If necessary a pliers can be used to unscrew the nut or cap Do not use a pipe wrench to tighten o...

Страница 22: ...on threads Teflon tape must be used on threads of the 1 NPT connection and on the threads for the drain line connection Teflon tape is not necessary on the nut connection nor caps because of o rings...

Страница 23: ...ss Handle 2 7 109479 Bypass Rotor Seal Retainer 2 8 102159 O Ring 135 2 9 102161 O Ring 112 2 10 102160 O Ring 214 2 Bypass Valve Not Shown Bypass Vertical Adapter Assembly ORDER NO DESCRIPTION QTY 10...

Страница 24: ...ants on threads Teflon tape must be used on threads of the 1 NPT connection and on the threads for the drain line connection Teflon tape is not necessary on the nut connection nor caps because of o ri...

Страница 25: ...ble the valve the wrench shown in various positions on the valve may be purchased to aid in assembly or disassembly Wrench part number is 102892 Loosens Drain Nut in Polytube Applications Loosens Driv...

Страница 26: ...minutes of no water usage when gallon capacity reaches 0 1 to 28 1 to 28 1 to 28 20 to 250 000 20 to 250 000 20 to 250 000 20 to 250 000 Reserve Gallons Regeneration Type Days Override Results Reserv...

Страница 27: ...27 NOTES...

Страница 28: ...s paragraph sets forth the exclusive remedy for any valid warranty claims against Hellenbrand THIS WARRANTY DOES NOT COVER defects caused by sand sediment or bacteria fouling accident fire flood Act o...

Отзывы: