13

STEP 6CS  – No Hard Water Bypass Enabled - Selection requires that a connection to a 

Motorized Alternator Valve (MAV) is made to the two pin-connector labeled ALTERNATOR MAV 

DRIVE located on the printed circuit board.  The MAV will be driven closed before the first re-

generation cycle that is not FILL or FILTERING, and be driven open after the last regeneration 

cycle that is not FILL.   NOTE: If the control valve enters into an error state during regeneration 

mode, the no hard water bypass valve will remain in its current state until the error is corrected 

and reset.  Press NEXT to go to Step 10CS.

STEP 7CS  – Configuring the Control Valve for Separate Source Operation - Select 

Separate Source Enabled for control operation.  For separate source operation, the three wire 

connector is not used.  Selection requires that a connection to a MAV is made to the two pin 

connector labeled ALTERNATOR MAV DRIVE located on the printed circuit board.  The C 

port of the MAV must be connected to the valve inlet and the A port connected to the separate 

source used during regeneration.  The B port must be connected to the feed water supply.  

When set to Separate Source Enabled the MAV will be driven closed before the first regeneration 

cycle, and be driven to open after the last regeneration cycle.

NOTE: If the control valve enters into an error state during regeneration mode, the MAV will 

remain in its current state until the error is corrected and reset.  Press NEXT to go to Step 

10CS.

STEP 8CS  – Configuring the Control Valve for Water Reclamation Mode - Select Reclama-

tion Enabled for control operation.  Motorized Alternating Valve will advance to Bypass at a set 

time after the beginning of regeneration, and return to Service after a set duration.  
The start of regeneration is defined as the first cycle that is not FILL or FILTERING.  The 

Alternating MAV will transition back to Service after the completion of the preset duration time, 

labeled Reclaim Duration.  Three reclaim events are possible.  Select either Reclaim Enabled, 

Reclaimed 2x for two events and Reclaim 3X for three separate reclaim events.

ENABLED

NO HARD BYPASS
SET 

STEP 6CS

SEPARATE SOURCE
SET 

STEP 7CS

ENABLED

RECLAIM
SET 

STEP 8CS

ENABLED

STEP 5CS

DELAYED RINSE & FILL
SET 

OFF

MIN

STEP 5CS – This option delays the last two cycles of regeneration (only "Rinse" and "Fill"). 

Filter must be programmed as post fill. This feature splits the regeneration into two por-

tions.  The first portion of the regeneration will start immediately and all programmed cycles 

before the "Rinse" and "Fill" cycles will be performed.  After all programmed cycles before 

"Rinse" and "Fill" are completed the control valve will drive to the stand-by position (display-

ing "Delayed Rinse + Fill Pending").  When the volume of the on-line unit is depleted to 10% of 

its programmed capacity, the control valve will be triggered to finish the second portion of the 

regeneration and complete the "Rinse" and "Fill" cycles and return to Service and be placed 

into Standby mode, to wait to come on-line for service.  Press NEXT to go to Step 10CS.

Use the 

 

or 

 

buttons to select minutes after start of regeneration to activate MAV to 

reclaim position for 1st reclaim event.  Press NEXT to set duration of reclaim.

Use the 

 

or 

 

buttons to select minutes of 1st reclaim duration.  Press NEXT to go 

to next reclaim event if more than one event is selected.  Press NEXT to go to Step 

10CS.  If only one reclaim event is selected.

Only displays if more than one reclaim event if selected.  Use the 

 

or 

 

buttons to 

select the number of minutes after start of regeneration for second reclaim event.

Press NEXT to program second reclaim duration.  Use the 

 

or 

 

buttons to set 

length of second duration.
Press NEXT to program third reclaim event or to go to Step 10CS.

MAV RECLAIM START
SET 

10:00

MIN 

RECLAIM DURATION
SET 

15:00

MIN 

MAV RECLAIM 2 START
SET 

26:00

MIN 

RECLAIM 2 DURATION
SET 

10:00

MIN 

Содержание ProMate-6.0

Страница 1: ...Owner s Filter Manual Manufactured by HELLENBRAND INC 404 Moravian Valley Road Waunakee Wisconsin 53597 www hellenbrand com info hellenbrand com FILTER SYSTEM 107207 Rev B 5 8 18 2007 2018...

Страница 2: ...assistance for servicing your water filter please contact the dealer who installed this system Job Specification Sheet 2 Pre Installation Check List 3 Installation Instructions 4 Programming 5 Initia...

Страница 3: ...recommended with all electric controls Existing Plumbing Condition of existing plumbing must be free from lime and iron build up Piping that is built up heavily with lime and or iron must be replaced...

Страница 4: ...joints should be cool and solvent cements should be set before installing the nut split ring and o ring Avoid getting primer and solvent cement on any part of the o rings split rings bypass valve or...

Страница 5: ...cally When water is being treated i e water is flowing through the system the word GPM flashes on left side of display when other than flow rate is displayed Figure 8 DAYS TO A REGEN 6 CAPACITY REMAIN...

Страница 6: ...to prevent multiple units from regenerating at the same time Step 5I Regeneration Time minutes Set the minutes of day for regeneration using or buttons This display will not be shown if system is set...

Страница 7: ...vide treated water when the regeneration has been completed Figure 11 STEP 1S STEP 2S FILTERING STEP 3S SET 12 00MIN STEP 1S Press NEXT and simultaneously for 3 seconds If screen in Step 2S does not a...

Страница 8: ...tivates after set time Press NEXT for programming Relay Triggered on Gallons Relay activates every set number of gallons while in service and deactivates after set time Press NEXT to go to 11S for pro...

Страница 9: ...arrows to set duration of relay activation in minutes Range 0 01 1 second 500 00 500 minutes Press NEXT to go to Step 20S Press REGEN to return to previous step STEP 13S If REGEN gallons chosen to act...

Страница 10: ...his display will show dashes if a water meter is not installed Press the NEXT button at any time to go to Step 6 D Press REGEN to return to the previous step DIAGNOSTICS STEP 1D STEP 2D 2 DAYS SINCE R...

Страница 11: ...on at time of stall Press NEXT to exit valve history STEP 1VH VALVE HISTORY STEP 2VH 970 TOTAL DAYS STEP 3VH 235 STEP 4VH 175 GAL x1K RETURN TO NORMAL MODE Can not be reset TOTAL REGENS TOTAL GALLONS...

Страница 12: ...No Hard Water Bypass During Regeneration See instructions in Step 6CS Reclaim Enabled Allows control to operate in Reclamation Mode up to 3 reclaim events can be programmed See instructions in Step 8C...

Страница 13: ...ating MAV will transition back to Service after the completion of the preset duration time labeled Reclaim Duration Three reclaim events are possible Select either Reclaim Enabled Reclaimed 2x for two...

Страница 14: ...to return to previous step Only displays if RECLAIM 2X is selected Use the or buttons to select number of minutes after start of regeneration for Aux MAV to divert waste water Press NEXT to program n...

Страница 15: ...or buttons until selection of fourth cycle appears in left upper corner in this example RINSE is selected Press NEXT to go to Step 18CS Press REGEN to return to previous step STEP 18CS Press the or bu...

Страница 16: ...osen drive cap gear 1 4 turn timed out trying to reach next position C2 Address high drive forces C3 Motor failure during regeneration replace motor Error Code 104 Motor ran too long D1 Piston unable...

Страница 17: ...ce battery if less than 3 volts F Defective PC board F Replace PC board 3 Control does not display correctly A Power outage 2 years A Reset time of day replace lithium coin type battery time of day on...

Страница 18: ...r assembly C Defective relay See figure below C Replace Relay D Defective PC Board D Replace PC Board E Faulty wire connections between E Check and repair wire connections PC board and relay 7 Relay e...

Страница 19: ...6 21 x 62 1 110569 5 Filter Media Contact dealer for filter media type quantity 6 Underbedding Contact dealer for underbedding type quantity Vortech tank does not use underbedding Owners Manual 1 1072...

Страница 20: ...OVER AND DRIVE ASSEMBLY After completing any valve maintenance involving the drive assembly or the drive cap assembly and pistons press and hold NEXT and REGEN buttons for 3 seconds or unplug power so...

Страница 21: ...The nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench If necessary a pliers can be used to unscrew the nut or cap Do not use a pipe wrench to tighten o...

Страница 22: ...on threads Teflon tape must be used on threads of the 1 NPT connection and on the threads for the drain line connection Teflon tape is not necessary on the nut connection nor caps because of o rings...

Страница 23: ...ss Handle 2 7 109479 Bypass Rotor Seal Retainer 2 8 102159 O Ring 135 2 9 102161 O Ring 112 2 10 102160 O Ring 214 2 Bypass Valve Not Shown Bypass Vertical Adapter Assembly ORDER NO DESCRIPTION QTY 10...

Страница 24: ...ants on threads Teflon tape must be used on threads of the 1 NPT connection and on the threads for the drain line connection Teflon tape is not necessary on the nut connection nor caps because of o ri...

Страница 25: ...ble the valve the wrench shown in various positions on the valve may be purchased to aid in assembly or disassembly Wrench part number is 102892 Loosens Drain Nut in Polytube Applications Loosens Driv...

Страница 26: ...minutes of no water usage when gallon capacity reaches 0 1 to 28 1 to 28 1 to 28 20 to 250 000 20 to 250 000 20 to 250 000 20 to 250 000 Reserve Gallons Regeneration Type Days Override Results Reserv...

Страница 27: ...27 NOTES...

Страница 28: ...s paragraph sets forth the exclusive remedy for any valid warranty claims against Hellenbrand THIS WARRANTY DOES NOT COVER defects caused by sand sediment or bacteria fouling accident fire flood Act o...

Отзывы: