FILTER SETUP
Manual Regeneration
Sometimes there is a need to regenerate the system, sooner than when the system calls for it,
usually referred to as manual regeneration. There may be a period of heavy water usage because
of guests or a heavy laundry day.
To initiate a manual regeneration at the preset delayed regeneration time, press and release
“REGEN”. The words “REGEN TODAY” will flash in left corner of display to indicate that the
system will regenerate at the preset delayed regeneration time. If you pressed the “REGEN”
button in error, pressing the button again will cancel the request.
To initiate a manual regeneration immediately, press and hold the “REGEN” button for three
seconds. The system will begin to regenerate immediately. The request cannot be cancelled. You
must cycle all the way through the cycles to make it stop. PLEASE NOTE: This will reset the meter.
Regeneration Mode
Typically a system is set to regenerate at a time of low water usage. An example of a time with low
water usage is when the household is asleep. If there is a demand for water when the system is
regenerating, untreated water will be supplied.
When the system begins to regenerate, the display will change to include information about the step
of the regeneration process and the time remaining for that step to be completed. The system runs
through the steps automatically and will reset itself to provide treated water when the regeneration
has been completed.
Figure 11
STEP 1S
STEP 2S
FILTERING
STEP 3S
SET
12:00
MIN
➔
➔
➔
STEP 1S – Press NEXT and
simultaneously for 3 seconds. If screen in Step 2S does
not appear in 5 seconds the lock on the valve is activated.
STEP 2S – Select between softening or filtering. A flashing "SOFTENING" or
"FILTERING" will appear. Choose FILTERING using
or
button. Factory setting is
Filtering. Press NEXT to go to Step 3S. Press REGEN to exit Filter System Setup.
STEP 3S – Select the time for the first cycle (which in this example is BACKWASH) using
the
or
button. Press NEXT to go to Step 4S. Press REGEN to return to previous step.
3
"REGEN TODAY" DAYS TO A REGEN
Regeneration Step
(shows time remaining in regen step
is 8 minutes, 22 seconds)
REGEN
8:22
BACKWASH
=
Up Arrow =
Down Arrow
Tank Diameter
10”
12”
13”
14”
16”
18”
Square Ft Area
0.545
0.785
0.921
1.07
1.38
1.76
Back wash Rate GPM
5
8
10
12
15
20
Backwash rates illustrated above are based upon 8-12 GPM per square foot of area and water with a temperature of 50º F. These
flow rates are typical for use with medias such as Carbon; Multi-Media, Neutralizing Media, or Birm. Specific media and conditions
may require specific flow rates.
GENERAL FILTER BACKWASH FLOW RATES
8" Through 13" Diameter Tanks
Regeneration Cycle Minutes
1st Cycle Backwash
12
2nd Cycle Rapid Rinse 6
14" and Larger Diameter Tanks
Regeneration Cycle Minutes
1st Cycle Backwash
20
2nd Cycle Rapid Rinse 10
All filters factory set to backwash every 3 days except neutralizing filters are set to backwash every 2 days.
Factory Settings:
SET
BACKWASH TIME