6
INSTALLER PROGRAMMING
Step 1
I
- Press NEXT and
simultaneously for 3 seconds.
This display may not appear on standard filtering mode.
Step 2
I
- Hardness: Not Applicable (nA) Press NEXT to go to Step 3.
Step 3
I
- Day Override: This sets the number of days between regenerations. If
value set to “oFF” regeneration initiation is based solely on gallons used. If value
is set as a number (allowable range from 1 to 28) a regeneration initiation will be
called for on that day even if sufficient number of gallons were not used to call
for a regeneration. Set Day Override using
or
buttons: Factory setting is 3
days.
• number of days between regeneration (1 to 28); or
• “oFF”
Press NEXT to go to step 4. Press REGEN to return to previous step.
Step 4
I
- Regeneration Time (hour): Set the hour of day for regeneration using
or
buttons. AM/PM toggles after 12. The factory setting time is 12:30
a.m. This display will show REGEN IMMEDIATE ON ZERO GAL if system is set
for immediate regeneration. See page 27. Press NEXT to go to step 5. Press
REGEN to return to previous step.
Note: When installing this unit as part of a multi unit parallel system the re-
gen time of day must be staggered to prevent multiple units from regenerating
at the same time.
Step 5
I
- Regeneration Time (minutes): Set the minutes of day for regeneration
using
or
buttons. This display will not be shown if system is set for immedi-
ate regeneration. Press NEXT to exit Installer Displays/Settings. Press REGEN to
return to previous step.
Figure 10
RETURN TO
NORMAL MODE
STEP 1I
STEP 2I
WATER HARDNESS
STEP 3I
DAYS BETWEEN REGEN
3
STEP 4I
REGEN TIME HOUR
12:30
AM
NA
STEP 5I
REGEN TIME MINUTES
12:30
AM
➔
➔
➔
➔
=
Up Arrow =
Down Arrow
=
Up Arrow =
Down Arrow
Step 1 - Press SET CLOCK.
Step 2 - Current Time (hour): Set the hour of the day using
or
buttons.
AM/PM toggles after 12. Press NEXT to go to step 3.
Step 3 - Current Time (minutes): Set the minutes of day using
or
buttons. Press NEXT to exit Set Clock. Press REGEN to return to previous
step.
Power Loss - Lithium battery on circuit board provides up to 2 years of
time clock backup during power outages. If the power is out when battery
is depleted, only time of day needs to be reset, all other values are stored
in non-volatile memory. When time of day is flashing, replace lithium coin
type 2032 battery.
Battery back-up feature will be activated after 24 hours of power.
Do not forget to reset for daylight savings time.
SET TIME OF DAY
Figure 9
➔
STEP 1
➔
STEP 2
SET TIME
6:35
PM
➔
SET TIME
6:35
PM
STEP 3
SET
RETURN TO ROTATING DISPLAY
GR
SET
SET
SET
SET
➔
Содержание ProMate-6.0