26
PROGRAMMING OPTIONS
DELAYED
oFF
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity reaches 0.
DELAYED
oFF
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the specified number of days
between regenerations is reached.
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity reaches 0 or the
specified number of days between regenerations is reached.
IMMEDIATE
oFF
Reserve capacity not automatically estimated.
Regeneration occurs immediately when gallons capacity reaches 0.
Time of regeneration will not be allowed to be set because regeneration will always
occur on 0.
D IMMEDIATE
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when specified number of days be-
tween regenerations is reached or regeneration occurs immediately after 10 minutes
of no water usage when gallon capacity reaches 0.
1 to 28
1 to 28
1 to 28
20 to
250,000
20 to
250,000
20 to
250,000
20 to
250,000
Reserve
Gallons
Regeneration
Type
Days
Override
Results
(Reserve capacity estimate based on history of water usage)
OPERATING PRESSURES
Minimum/Maximum ................................................................................................................Minimum 30 psi
Optimum Range 40-65 psi
1
Maximum 100 psi
OPERATING TEMPERATURES
Minimum/Maximum .................................................................................................................................40º - 110º F
METER
Accuracy ..................................................................................................................................................±5%
Flow Rate Range ......................................................................................................................................0.25 - 27 GPM
Gallon Range ............................................................................................................................................20 - 250,000
DIMENSIONS
Drain Line .................................................................................................................................................3/4” or 1” NPT
Regenerant Line .......................................................................................................................................3/8” Poly Tube
ELECTRICAL CURRENT DRAW/VOLTAGE/FREQUENCY ...................................................................................0.5A/110v/60Hz
Compatible with the following regenerants or chemicals: Sodium chloride, potassium permanganate, sodium bisulfite, sodium hydroxide,
hydroxide, hydrochloric acid, chlorine and chloramines.
1
Operating outside of the optimum pressure range may affect system function. Contact your Hellenbrand support team for information.
GENERAL SPECIFICATIONS
*Factory settings in bold
To "lockout" access to modification settings, diagnostic and valve history displays except hardness, day override and time
press
X
next,
X
and clock in sequence to "unlock" press
X
next,
Z
and clock in sequence.
DELAYED