![Hella APS-R Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/hella/aps-r/aps-r_installation-and-configuration-manual_2121286035.webp)
n
The height is measured with the
“Refresh”
button in the topic
block
“Camera Position”
n
Applying the measured height ( Fig. 34/8) with the
“greater
than”
button ( Fig. 34/3) into the input field ( Fig. 34/5) sets the
install height of the counter. This value can be changed using
the spin control ( Fig. 34/4) or by inputting a value directly into
the input field.
n
Click the
“Save”
button ( Fig. 34/7) to save all the settings in
the device.
n
Click the
“Reset”
button ( Fig. 34/6) to go back to previous
settings.
n
Click the
“Range”
button ( Fig. 35/7) to see the unusable area
( Fig. 35/1) and usable area ( Fig. 35/2). The usable area is the
range where people can be tracked and counted.
n
Click the
“Floor Area”
button ( Fig. 35/6) to see the floor area
( Fig. 35/3) and the yellow floor area polygon line ( Fig. 35/4).
n
Define the floor area by moving/adding/deleting
points ( Fig. 35/5). The floor area is defined by a minimum of
3 points and a maximum of 20 points.
Range
Floor Area
Obstructions
1
2
Fig. 37: Live View with stairs in the floor area
n
If the floor area is uneven (e.g there are stairs) untick the
“Straight Floor”
n
The individual heights of the floor area polygon points will now
be shown, either as automatically assigned values ( Fig. 37/2)
or manually assigned values ( Fig. 37/1) if they have been
adjusted.
n
Click the
“Refresh”
button ( Fig. 36/3)to remeasure the
heights.
Setup for stairs, ramps and uneven
floors
1
2
3
4
Fig. 36: Floor area with stairs
Configuration
Camera Position
09.06.2017
35
The reproduction, distribution and utilization of this document as well as the communication of its contents to others
without express authorization is prohibited. Offenders will be held liable for the payment of damages.
All rights reserved in the event of the grant of patent, utility model or design.
Содержание APS-R
Страница 64: ......