4.5 Environmental conditions
Category
Compliance
Description
Ambient
temperature
EN 50125-1 class T3
Operation:
-25 °C to 70 °C
Storage:
-40 °C to 85 °C
Extended low temper-
ature range:
Cold start between
-40 °C and -25 °C will
not cause damage.
After warming up, the
unit will return to normal
operation without user
intervention.
Humidity
EN 50125-1
Annual average
<=75% (relative)
short-time maximum
95% to 100% (relative)
short-time maximum
30 g/m
3
(absolute)
Ingress
protection
DIN IEC 60529
IP65
In conjunction with
appropriate mating con-
nectors
Fire safety
DIN EN
45545-2:2015+A1:2015
grouping rule 1 applies
(less than 100 g com-
bustible mass)
ISO 3795 / UL94
UL94 Class V0
Shock and
vibration
EN 50125-1
IEC 61373 cat. 1, class
B
(applied test methods
and limits required for
EN 50155 conformity)
Electromag-
netic compat-
ibility
EN 50121-3-2:2015
EMV 06
(applied test methods
and limits required for
EN 50155 conformity)
Technical data
Environmental conditions