CCR961 MANUAL-GB
41
Version B2:01-07-2015
FROM master
IM184
Bit
Port
PA
0
Step bit 0
1
Step bit 1
2
Step bit 2
3
4
5
6
7
Status req.
if = 1 cancel step info and set "tx status"
PB
0
Master bit
positive edge trig !!
1
2
3
Set time = 12.00
if = 1 set ccr time to 12.00 (noon)
4
0=tx status 1=tx analog
5
analog pointer 0
(Iout=11H, Lamp=31H, Uout=51, E=71H)
6
analog pointer 1
7
analog pointer 2
TO master
IM184
Bit
Port
PC
0
Step bit 0
1
Step bit 1
2
Step bit 2
3
4
5
6
7
Lamp error 1
PD
0
Lamp error 2
1
E min1
2
E min2
3
I min
4
I max
5
Remote
6
7
0=status
PC
0
12 bit analog lsb
1
12 bit analog
2
12 bit analog
3
12 bit analog
4
12 bit analog
5
12 bit analog
6
12 bit analog
7
12 bit analog
PD
0
12 bit analog
1
12 bit analog
2
12 bit analog
3
12 bit analog msb
4
analog pointer 0
(Iout=8xH, Lamp=9xH, Uout=ax, E=bxH)
5
analog pointer 1
(analog p bit7)
6
analog pointer 2
7
1=analog
Содержание CCR 961-SW4.00
Страница 1: ...Regulator type CCR 961 SW4 00 USER MANUAL GB...
Страница 9: ...CCR961 MANUAL GB 9 Version B2 01 07 2015...
Страница 13: ...CCR961 MANUAL GB 13 Version B2 01 07 2015...
Страница 19: ...CCR961 MANUAL GB 19 Version B2 01 07 2015 CCR front view...
Страница 36: ...CCR961 MANUAL GB 36 Version B2 01 07 2015...