10
Fan unit ELS EC..
Installation and Operating Instructions
Commissioning without a filter is not permitted, as otherwise the unit and entire duct system will be contamina-
ted. The functionality of the fire damper may be affected by contamination. This can be prevented through regular
cleaning.
Non-observance will result in a loss of warranty.
Special installation situations – plaster compensation
– casing too deep:
If the casing has been fitted too deep into the wall, the facade can be fixed with longer plastic screws (suitable plastic
screws are provided for each facade, scope of delivery: per 2 pcs, 25 mm and 40 mm).
6.3 Installation of presence sensor ELS EC.. P types
Detection angle horizontal approx. 100°, vertical approx. 80° (see Fig. 21, range information see section 7.3).
After the installation of the fan unit in the flush-mounted/surface-mounted casing, the sensor hanging from the cable
must be clipped in the provided opening on the rear of the facade frame (see Fig. 15/16). The correct position of the
sensor is ensured by a guide. Before mounting the facade frame, the sensor cable must be stored carefully (do not
clamp or mechanically load the cable).
Subsequently mount and screw the facade frame into place.
- Do not allow facade frame with mounted sensor to hang freely from the sensor cable, as otherwise the sensor
and control unit could be damaged.
- The sensor contains a very sensitive electronic component and it must not be opened or damaged in any
case.
6.4 Installation of humidity sensor ELS EC.. F types
After the installation of the fan unit in the flush-mounted/surface-mounted casing, the humidity sensor hanging from the
cable must be clipped in the provided opening on the rear of the facade frame (see Fig. 17/18). The correct position of
the sensor is ensured by a guide. Before mounting the facade frame, the sensor cable must be stored carefully (do not
clamp or mechanically load the cable).
Subsequently mount and screw the facade frame into place.
- Do not allow facade frame with mounted sensor to hang freely from the sensor cable, as otherwise the sensor
and control unit could be damaged.
- The sensor contains a very sensitive electronic component and it must not be opened or damaged in any
case.
m
CAUTION
m
CAUTION
m
CAUTION
Fig.16
Fig.15
80°
vertical
100°
horizontal
Fig.17
Fig.18
EN
Содержание 6355
Страница 23: ...21 Ventilatoreinsatz ELS EC Montage und Betriebsvorschrift DE ...
Страница 24: ...22 Ventilatoreinsatz ELS EC Montage und Betriebsvorschrift DE ...
Страница 47: ...21 Fan unit ELS EC Installation and Operating Instructions EN ...
Страница 48: ...22 Fan unit ELS EC Installation and Operating Instructions EN ...
Страница 50: ...24 Fan unit ELS EC Installation and Operating Instructions EN ...
Страница 51: ...25 Fan unit ELS EC Installation and Operating Instructions EN ...