7 Error Handling
38
Programmer PG 02
- Exchange actuator
- Check numbers of teeth (1
TeethPickUp1
and 2
TeethPickUp2
)
- With vehicle operation, check whether overspeed was due to
thrust operation.
3005 ErrSetpoint1Extern
3105 SErrSetpoint1Extern
3006 ErrSetpoint2Extern
3106 SErrSetpoint2Extern
3007 ErrLoadInput
3107 SErrLoadInput
3008 ErrSyncInput
3108 SErrSyncInput
3009 ErrBoostPressure
3109 SErrBoostPressure
3010 ErrOilPressure
3110 SErrOilPressure
3012 ErrCoolantTemp
3112 SErrCoolantTemp
3013 ErrChargeAirTemp
3113 SErrChargeAirTemp
3014 ErrOilTemp
3114 SErrOilTemp
3019 ErrExcitReduct
3119 SErrExcitReduct
3020 ErrSpeedReduct
3120 SErrSpeedReduct
3021 ErrCoolantPressure
3121 SErrCoolantPressure
Cause:
Some error has been detected for the respective sensor input (e.g., short
circuit or cable break).
Response:
- Depending on the selection, the error may disappear automatically when
the values measured by the control are back within the error limits.
Action:
- Check sensor cable for short circuit or cable break.
- Check the respective sensor, replace if necessary.
- Check error limits for this sensor.
3030 ErrOilPressWarn
3130 SErrOilPressWarn
Cause:
Oil pressure has dropped below the speed dependent oil pressure warning
characteristic.
Response:
- Error message.
- Error is cleared automatically when oil pressure is back above the oil
pressure warning characteristic.
Action:
- Check engine (oil level, oil pump, etc., ...).
- Check oil pressure sensor.
- Check cable of oil pressure sensor.
- Check oil pressure warning characteristic
3031 ErrOilPressEcy
3131 SErrOilPressEcy