9 Control Unit DC 2005DP.2 - 01 up to DC 2040DP.2 - 01
22
HELENOS V
9.1.2
Inputs and Outputs
Supply voltage sensors
Input voltage
Reference Voltage setpoint adjuster
U
ref
= 5 V DC, I
max
= 20 mA (10 mA)
2 Speed inputs
for Inductive sensor
1 Temperature input
for PT 1000
1 Temperature input
for NTC
4 Analogue inputs
U = 0..5 V, f
g
= 16 Hz
or I = 4 .. 20 mA, f
g
= 16 Hz
4 Digital inputs
R
pd
= 2,2 k
Ω
, f
g
= 160 Hz
4 Digital /PWM- In- Outputs
R
pu
= 2,2 k
Ω
, I
sink
< 0,1 A, f
g
= 160 Hz
2 Analogue Outputs Current
I
out
= 0 .. 22,5 mA, R
max
= 470
Ω
(125
Ω
)
2 Analogue Outputs Voltage
U
out
= 0 .. 5 V, R
min
= 250
Ω
(500
Ω
)
1 PWM-Output
I
sink
< 3 A
2 Digital Outputs failure lamp
High-Side-Switch, I
max
< 3 A
Actuator position sensing
U
Reg.weg
= 1,4 ..3,0 V, U
ref
= 8 V, I
ref
< 20 mA
Drive output
PWM with 2000 Hz, I
eff
< 6,4 A
Serial Interface
ISO 9141, Heinzmann Communication
9.2
Mounting
When selecting the location, care should be taken for easy access in order to facilitate read-
out of the failure indication and replacement of the device under field conditions. Any
mounting position is admissible. When fitting the device directly on the engine, it should
be mounted using vibration absorbers.