67
Blower continues
to operate
and display
shows a higher
than setting
temperature.
Water level is low.
Add water.
Refer to
“Filling the Furnace initially
with Water.”
Defective Electronic
Controller.
Replace Electronic
Controller.
Refer to
“electrical (electronic
controller)”
Defective temperature
probe.
Replace temperature
probe.
Refer to
“electrical (temperature
Probe)”
Losing Water
Furnace is boiling (could
happen when away,
sleeping or at work).
Add water. Complete a
full furnace check of all
systems.
Refer to
“Filling the Furnace initially
with Water.”
Very slow leak
somewhere in the
system.
Check and tighten any
leaking fittings.
Contact your
Local Dealer
.
Someone is taking hot
water from the system
when needed.
Add water.
Refer to
“Water Level Maintenance.”
Someone has
accidentally opened
a valve and not told
anyone.
Add water.
Refer to
“Water Level Maintenance.”
Leaking water line.
Fix leak in water line.
Contact your
Local Dealer
.
Bladder is leaking.
Replace bladder.
Refer to
“Bladder.”
Bladder gate valve needs
adjusting.
Adjust and tighten
gate valve.
Refer to
“Bladder Gate valve and
Bladder hose.”
PrOBLeM
cause
sOLutiOn