![Heatmor 200 SSP Скачать руководство пользователя страница 71](http://html1.mh-extra.com/html/heatmor/200-ssp/200-ssp_user-manual_2117598071.webp)
66
Firebox receiving air
somewhere when
fans are off.
Check all seals
for air leaks.
Run a smoke check.
Refer to
“checking for air Leaks.”
Fire is not burning hot.
Check type of wood
pellets burning and
if blower is working
properly.
Refer to
“What can i burn,
combustion air Blower /
Flipper assembly”
Burning wood pellets that
are too wet.
Add wood pellets with
the correct moisture
content.
Refer to
“What can i Burn”
Air flow is not sufficient
for the type of fuel.
Check and clean fan
blades. Check and
clean flipper assembly.
Refer to
“combustion air Blower /
Flipper assembly”
Ashes in Air Box(s).
Clean Air Box(s).
Refer to
“air Box.”
Chimney Plugged.
Clean Chimney.
Refer to
“chimney”
Flue plugged.
Clean Flue.
Refer to
“Flue.”
Water temperature not
being held in the 165 to
185 degree range
Consult Dealer.
Contact your
Local Dealer
.
thermometer
(temp gauge)
exceeds
212 degrees
Fahrenheit.
Furnace is not
boiling.
Low water level
Add water.
(Let Furnace cool first)
Refer to
“Water Level Maintenance.”
charcoal build-up
in firepot.
Excessive ashes.
Remove ashes.
Refer to
“ash Management and ash
removal.”
Burning wood pellets with
a high ash content
Burn wood pellets with
low ash content
Refer to
“What can i Burn”
PrOBLeM
cause
sOLutiOn
PrOceDure