69
cannot get
building(s) warm
enough.
Insufficient heating
devices in building.
Consult Dealer.
Contact Your
Local Dealer.
Improperly installed
heating devices
in building.
Correct installation of
heating devices.
Contact Your
Local Dealer.
Heating devices need
maintenance.
Maintain heating
devices.
Contact Your
Local Dealer.
HEATMOR™ not running
between 145-185
degrees Fahrenheit.
Consult Dealer.
Contact Your
Local Dealer.
Insufficient water
circulation from
HEATMOR™.
a) Check circulating
pumps. Replace if
necessary .
b) Line that is kinked.
c) Air in system.
d) Need a larger pump.
e) Lines are too small.
f) Pump has a
restriction in the intake
(piece of plastic or foil).
Contact Your
Local Dealer.
Refer to
“installation Manual.”
Unbalanced supply water
distribution.
Re-balance and
distribute water from
outdoor furnace.
Balance the system by
adjusting the flows of
water to the different
heating appliances.
Contact your
Local Dealer.
Refer to
Installation Manual.
One appliance getting
more than it’s share of
the total flow of hot water.
Balance the system by
adjusting the flows of
water to the different
heating appliances.
Contact your
Local Dealer.
Defective in house
(building) thermostat and
controls.
Replace thermostats
and controls.
Contact your
Local Dealer.
PrOBLeM
cause
sOLutiOn
PrOceDure