MiniMuM cLearance seParatiOn sPeciFicatiOns
The HEATMOR™ furnace, is certified to be installed outside, away from other buildings. Please observe the
following “Clearance to Combustibles” guidelines. If you have any further questions, which are not addressed
in this Operators Manual, please contact your local dealer for further information.
♦
To HEATMOR™ Stainless Steel Outdoor Furnace
Back.
96 inches
♦
To HEATMOR™ Stainless Steel Outdoor Furnace
top.
18 inches
♦
To HEATMOR™ Stainless Steel Outdoor Furnace
Front.
48 inches
♦
To HEATMOR™ Stainless Steel Outdoor Furnace
chimney.
18 inches
♦
To HEATMOR™ Stainless Steel Outdoor Furnace
sides.
6 inches
♦
Do not
store combustible liquids or materials near the furnace.
♦
It is not recommended to install the furnace in any form of building.
Before installing your HEATMOR™ Stainless Steel Outdoor Furnace, if in the
united states
, always check
any and all applicable state and local regulations and inform your insurance agent.
Before installing your HEATMOR™ Stainless Steel Outdoor Furnace, if in
canada
, always check any and all
applicable Provincial and Municipal regulations and inform your insurance agent.
HEATMOR™ Inc. strongly recommends not installing a HEATMOR™ Stainless Steel Outdoor Furnace within
50 feet of any flammable structure.
A HEATMOR™ Stainless Steel Outdoor Furnace should be located with consideration to your neighbor’s
property and in accordance with local ordinances. Refer to the “Best Burn Practices” for further operating
considerations.
HEATMOR™ Outdoor Furnace, is not designed or certified to be located in densely populated areas.